1/10 and 10-Gigabit Layer 2/3 Ethernet Switches User’s Manual
5-100
Timers
Clicking the TIMERS tab brings up the 802.1X TIMER CONFIGURATION page (Figure 5-84),
which configures Timer parameters at the individual port level. The parameters for this
page are shown in Table 5-12.
Port Initialize
This parameter specifies the initialization control for the port. Setting this value to
True causes the port to be initialized. The value reverts to False once
initialization is complete.
Maximum
Authentication
Request
This parameter specifies the maximum number of authentication requests that
can be sent from the authenticator before getting a response from the supplicant.
Reauthentication
This parameter provides configuration to enable or disable the reauthentication
mechanism on the port.
Figure 5-84. 802.1x Timer Configuration Page
Table 5-61. 802.1x Timer Configuration Page Parameters
Parameter Description
Port
This parameter is the index of the port for which fields such as QUIET PERIOD,
T
RANSMIT PERIOD, and such are configured.
Quiet Period
(Seconds)
This parameter specifies the duration for which the authenticator will be silent
and will not attempt to acquire a supplicant. It can be configured to any value in
the range from 1 to 65535 seconds.
Table 5-60. 802.1x Port Settings Page Parameters (Continued)
Parameter Description
Page view 151