Supermicro SYS-6015C-URV Datasheet Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
6-10
S
UPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual
Simply push the new power supply module into the power bay until you hear
a click.
Finish by plugging the AC power cord back into the module.
6015C-U/6015C-NT
The SuperServer 6015C-U/6015C-NT has a single 560 watt power supply, which
is auto-switching capable. This enables it to automatically sense and operate with
a 100v - 240v input voltage.
Power Supply Failure
If the power supply module fails, the system will shut down and you will need to
replace the module. Replacements can be ordered directly from Supermicro (see
contact information in the Preface). As there is only one power supply module in
the 6015C-U/6015C-NT, power must be completely removed from the server before
removing and replacing the power supply for whatever reason.
Replacing the Power Supply
First turn the power switch on the control panel off, then unplug the power cord
from the system. Replace with the same model (p/n PWS-561-1H20), which can be
ordered directly from Supermicro (see Contact Information in the Preface).
Remove the screws that secure the power supply to the chassis then pull
the module straight out with the handle provided (see Figure 6-6, redundant
power supply server shown). The power supply wiring was designed to de-
tach automatically when the module is pulled from the chassis.
Carefully insert the new power supply into the open bay and push it com-
pletely into the chassis until you hear a clicking sound, meaning it has been
fully inserted.
Secure it to the chassis with the screw you removed previously, then recon-
nect the AC power cord and depress the power button on the control panel to
restart the system.
5.
6.
1.
2.
3.
Page view 67