Supermicro SYS-6015C-URV Datasheet

Browse online or download Datasheet for Server barebones Supermicro SYS-6015C-URV. Supermicro SYS-6015C-URB server barebone User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SUPERSERVER 6015C-UR
S
UPERSERVER 6015C-U
SUPERSERVER 6015C-NTR
SUPERSERVER 6015C-NT
SUPER
®
USER’S MANUAL
1.0
Page view 0
1 2 3 4 5 6 ... 109 110

Summary of Contents

Page 1 - SUPER

SUPERSERVER 6015C-UR SUPERSERVER 6015C-U SUPERSERVER 6015C-NTR SUPERSERVER 6015C-NT SUPER®USER’S MANUAL1.0

Page 2 - Release Date: May 12, 2008

1-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6015C-UR/6015C-U/6015C-NT

Page 3 - Manual Organization

A-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualNotes

Page 4

Appendix B: BIOS POST CodesB-1Appendix B BIOS POST CodesThis section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are div

Page 5

B-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualPOST Code Description16h 1-2-2-3 BIOS ROM checksum17h Initialize cache

Page 6 - Table of Contents

Appendix B: BIOS POST CodesB-3POST Code Description5Ch Test RAM between 512 and 640 kB60h Test extended memory62h Test extended memory a

Page 7 - Chapter 4 System Safety

B-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualPOST Code Description9Ch Set up Power Management9Dh Initialize security

Page 8

Appendix B: BIOS POST CodesB-5The following are for boot block in Flash ROMPOST Code DescriptionE0h Initialize the chipsetE1h Initialize the

Page 9 - Introduction

B-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualNotes

Page 10 - 1-2 Serverboard Features

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single or dual Intel® Xeon® 5400/5300/5200/5100 Sequence processo

Page 11 - 1-3 Server Chassis Features

C-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualExpansion Slots 6015C-UR/6015C-U: Right side: one low-profi le PCI-E

Page 12 - Cooling System

C-3Appendix C: System Specifi cationsOperating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º

Page 13 - System Block Diagram

1-3Chapter 1: IntroductionATI Graphics ControllerThe X7DCU features an integrated ATI video controller based on the ES1000 graph-ics chip. The ES1000

Page 14 - 1-4 Contacting Supermicro

C-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualNotes

Page 15 - Server Installation

1-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFront Control PanelThe chassis' control panel provides you with system monit

Page 16 - Warnings and Precautions!

1-5Chapter 1: IntroductionFigure 1-1. Intel 5100/ICH9R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for d

Page 17 - Rack Mounting Considerations

1-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock

Page 18 - Installing the Inner Rails

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6015C-

Page 19 - Installing the Outer Rails

2-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in fro

Page 20

Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-ing them.Always keep the rack's fro

Page 21

2-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual2-4 Installing the System into a RackThis section provides information on instal

Page 22

Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a

Page 23

Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.Information in this document i

Page 24

2-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the Rack

Page 25 - System Interface

Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the 6015C-UR/60

Page 26 - 3-3 Control Panel LEDs

2-8SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual2-5 Checking the Serverboard SetupAfter you install the 6015C-UR/6015C-U/6015C-N

Page 27

Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System2-6 Checking the Drive Bay SetupNext, you should check to make sure t

Page 28 - 3-4 Hard Drive Carrier LEDs

2-10SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualChecking the Airfl owAirfl ow is provided by four sets of 4-cm fans (each set of f

Page 29 - System Safety

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca

Page 30

3-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualPowerThe main power button is used to apply or remove power from the power supply

Page 31 - 4-3 ESD Precautions

Chapter 3: System Interface3-3NIC2Indicates network activity on LAN2 when fl ashing.21NIC1Indicates network activity on LAN1 when fl ashing.HDDIndicates

Page 32 - BATTERY HOLDER BATTERY HOLDER

3-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual3-4 Hard Drive Carrier LEDsEach hard drive carrier has two LEDs.Green: When illu

Page 33 - Advanced Serverboard Setup

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Page 34 - Load plate released

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the inst

Page 35

4-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep t

Page 36

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Page 37 - 5-3 Connecting Cables

4-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is i

Page 38 - 5-4 I/O Ports

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks

Page 39 - 5-5 Installing Memory

5-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualIMPORTANT! Always connect the power cord last and remove it fi rst before adding,

Page 40 - Note: Notch

Chapter 5: Advanced Serverboard Setup5-3Socket keyCPU installed in socketPnP cap released from load plate3. Use your thumb and your index fi nger to ho

Page 41 - 5-6 Adding PCI Cards

5-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualWarning! We do not recommend that the CPU or the heatsink be removed. However, i

Page 42 - 5-7 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the serv

Page 43 - X7DCU Quick Reference

5-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 5-1. Front Control Panel Header Pins (JF1)other end of the cable to the Co

Page 44 - 5-8 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-75-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extrem

Page 45

SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chap

Page 46

5-8SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 5-3. Installing DIMM into SlotTo Install: Insert module vertically and pre

Page 47

Chapter 5: Advanced Serverboard Setup5-95-6 Adding PCI CardsPCI Expansion SlotsTwo riser cards are used to support add-on cards to the system. The SC8

Page 48

5-10SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 5-4. SUPER X7DCU Layout(not drawn to scale)5-7 Serverboard DetailsNote:

Page 49

Chapter 5: Advanced Serverboard Setup5-11X7DCU Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 5-9)JCF1 Compact Flash Ma

Page 50

5-12SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual5-8 Connector Defi nitionsPower LED The Power LED connection is located on pins 1

Page 51 - 5-9 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-13NIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located on pins 11 and 12 of JF1. Attach t

Page 52

5-14SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualReset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Att

Page 53 - 5-10 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThe X7DCU has eight headers, des-ignated Fan1 through Fan8. FAN1 through FAN6 are for chassis/syst

Page 54

5-16SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse p

Page 55

Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is desig-nated JWOL1. See the table on the right for pin definitions. You m

Page 57 - Supero Doctor III

5-18SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualUID SwitchesThere are two Unit Identifi cation (UID) switches on the motherboard.

Page 58

Chapter 5: Advanced Serverboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Page 59 - Advanced Chassis Setup

5-20SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable the on

Page 60 - 6-2 Control Panel

Chapter 5: Advanced Serverboard Setup5-215-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Page 61 - 6-3 System Fans

5-22SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual5-11 Floppy, IDE and SATA Drive ConnectionsNote the following when connecting t

Page 62 - Removing the Front Bezel

Chapter 5: Advanced Serverboard Setup5-23IDE ConnectorThere are no jumpers to con-fi gure the onboard IDE connec-tor. See the table on the right for pi

Page 63 - Accessing the Drive Bays

5-24SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual5-12 Installing SoftwareAfter the hardware has been installed, you should fi rst

Page 64 - SATA Drive Installation

Chapter 5: Advanced Serverboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management

Page 65

5-26SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp:/

Page 66

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 67 - 6-5 Power Supply

viSUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 68 - 6015C-U/6015C-NT

6-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe contro

Page 69

Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm heavy duty counter-rotating fans provide the cooling for the SuperServer 6015C-UR/6015C-U

Page 70

6-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay Installation/RemovalRemoving the Fr

Page 71 - Chapter 7

Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysSATA Drives: Because of their hotswap capability, you do not need to access the inside of

Page 72 - 7-3 Main BIOS Setup

6-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualSATA Drive InstallationThe SATA drives are mounted in drive carriers to simplify

Page 73 - Main Setup Features

Chapter 6: Advanced Chassis Setup6-7Installing/Removing a SATA DriveTo remove a carrier, push the release button located beside the drive LEDs.Swing t

Page 74 - Port5 and SATA Port6

6-8SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualDVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened

Page 75

Chapter 6: Advanced Chassis Setup6-9connects to drive A, and the connector that does not have twisted wires always connects to drive B.6-5 Power Suppl

Page 76 - 7-4 Advanced Setup

6-10SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualSimply push the new power supply module into the power bay until you hear a clic

Page 77

Chapter 6: Advanced Chassis Setup6-11Figure 6-6. Removing/Replacing the Power Supply

Page 78 - Memory Cache

viiTable of Contents2-5 Checking the Serverboard Setup ... 2-82-6 Checking the Driv

Page 79 - PCI Confi guration

6-12SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualNotes

Page 80 - Advanced Chipset Control

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the Phoenix BIOS™ Setup utility for the X7DCU. The Phoenix ROM BIOS is stored i

Page 81

7-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual7-2 Running SetupDefault settings are in bold text unless otherwise noted.The BIO

Page 82

Chapter 7: BIOS7-3Main BIOS Setup MenuMain Setup FeaturesSystem TimeTo set the system date and time, key in the correct information in the appropriate

Page 83 - CPU Cache Control

7-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual SATA Port1, SATA Port2, SATA Port3, SATA Port4, SATA Port5 and SATA Port6These

Page 84 - I/O Device Confi guration

Chapter 7: BIOS7-532 Bit I/OThis option allows the user to enable or disable the function of 32-bit data transfer. The options are Enabled and Disable

Page 85 - DMI Event Logging

7-6SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualSATA AHCI EnableSelect Enable to enable the Serial ATA Advanced Host Interface. (

Page 86 - Hardware Monitor Logic

Chapter 7: BIOS7-7Power Button BehaviorIf set to Instant-Off, the system will power off immediately as soon as the user hits the power button. If set

Page 87

7-8SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualMemory CacheCache System BIOS AreaThis setting allows you to designate a reserve

Page 88

Chapter 7: BIOS7-9Cache Extended Memory AreaIf enabled, this feature will allow the data stored in the extended memory area to be cached (written) int

Page 89

viiiSUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's Manual5-12 Installing Software ...

Page 90 - 7-5 Security

7-10SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualLatency TimerThis setting allows you to set the clock rate for the Bus Master. A

Page 91

Chapter 7: BIOS7-11Channel 0 Rank Sparing/Channel 1 Rank SparingSelect Enable to enable the function of memory sparing for Memory Bus Branch 0 or Bran

Page 92 - 7-6 Boot

7-12SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualAdvanced Processor OptionsAccess the submenu to make changes to the following s

Page 93 - 7-7 Exit

Chapter 7: BIOS7-13Adjacent Cache Line Prefetch (Available when supported by the CPU)The CPU fetches the cache line for 64 bytes if this option is set

Page 94 - Save Changes

7-14SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualI/O Device Confi gurationAccess the submenu to make changes to the following set

Page 95 - BIOS POST Messages

Chapter 7: BIOS7-15Base I/O AddressThis setting allows you to select the base I/O address for the Floppy port. The op-tions are Primary and Secondary.

Page 96

7-16SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualConsole TypeThis item allows you to choose the console redirection type. The op

Page 97

Chapter 7: BIOS7-17Voltage MonitoringThe following items will be monitored and displayed:Vcore A, Vcore B, -12V, P1V5, +3.3V, +12V, 5Vsb, 5VDD, P_VTT,

Page 98

7-18SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualIPMI (The option is available only when an IPMI card is installed in the system

Page 99

Chapter 7: BIOS7-19BIOS POST ErrorsEnabling this function to log POST errors. The options are Enabled and Dis-abled.BIOS POST Watch DogSet to Enabled

Page 100

Chapter 1 Introduction1-1 OverviewThe SuperServer 6015C-UR/6015C-U/6015C-NTR/6015C-NT is a high-end server comprised of two main subsystems: the SC815

Page 101 - BIOS POST Codes

7-20SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualRealtime Sensor DataThis feature display information from motherboard sensors,

Page 102 - POST Code Description

Chapter 7: BIOS7-21Supervisor Password Is:This indicates if a supervisor password has been entered for the system. Clear means such a password has not

Page 103

7-22SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualPassword on BootThis setting allows you to determine if a password is required f

Page 104

Chapter 7: BIOS7-237-7 ExitChoose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Ex

Page 105

7-24SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualSave ChangesHighlight this item and hit <Enter> to save any changes you ma

Page 106

A-1Appendix A: BIOS POST MessagesAppendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a prob-lem is

Page 107 - System Specifi cations

A-2SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupt

Page 108

A-3Appendix A: BIOS POST MessagesCPU ID:CPU socket number for Multi-Processor error.EISA CMOS not writeableServerBIOS2 test error: Cannot write to EIS

Page 109 - Regulatory Compliance

A-4SUPERSERVER 6015C-UR/6015C-U/6015C-NTR/6015C-NT User's ManualI/O device IRQ confl ictI/O device IRQ confl ict error.PS/2 Mouse Boot Summary Scre

Page 110

A-5Appendix A: BIOS POST MessagesPress <F2> to enter SetupOptional message displayed during POST. Can be turned off in Setup.PS/2 Mouse:PS/2 mou

Comments to this Manuals