SUPER®USER'S MANUALRevision 1.0SUPERSERVER6018R-WTR6018R-WTRT

Page 2

xSUPERSERVER 6018R-WTR(T) USER'S MANUALChapter 7 BIOS 7-1 Introduction ...

Page 3 - Manual Organization

7-12SUPERSERVER 6018R-WTR(T) USER'S MANUALChannel InterleavingThis feature selects from the different channel interleaving methods. The options a

Page 4

Chapter 7: BIOS7-13South BridgeThis feature allows the user to confi gure the settings for the Intel PCH chip.PCH InformationThis feature displays the

Page 5

7-14SUPERSERVER 6018R-WTR(T) USER'S MANUALSATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of ID

Page 6 - Table of Contents

Chapter 7: BIOS7-15SATA RAID Option ROM/UEFI DriverSelect Enabled to boot the system from a SATA RAID device or a UEFI (Unifi ed Extensible Firmware In

Page 7 - Chapter 3 System Interface

7-16SUPERSERVER 6018R-WTR(T) USER'S MANUALASPM SupportThis feature allows the user to set the Active State Power Management (ASPM) level for a PC

Page 8

Chapter 7: BIOS7-17Super IO Confi gurationSuper IO ChipDisplays the Super IO chip type.COM 1 Confi gurationSerial PortSelect Enabled to enable a seria

Page 9

7-18SUPERSERVER 6018R-WTR(T) USER'S MANUALSOL (Serial_Over_LAN) Device ModeUse this feature to select the desired mode for the SOL port. The opti

Page 10 - Chapter 7 BIOS

Chapter 7: BIOS7-19Data BitsUse this feature to set the data transmission size for Console Redirection. The options are 7 and 8 (Bits).ParityA parity

Page 11 - Introduction

7-20SUPERSERVER 6018R-WTR(T) USER'S MANUALPutty KeypadUse this feature to select function key and keypad setting on Putty. The options are VT100,

Page 12 - 1-2 Serverboard Features

Chapter 7: BIOS7-21Flow ControlThis feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over

Page 13 - 1-3 Server Chassis Features

Chapter 1 Introduction1-1 OverviewThe SuperServer 6018R-WTR(T) is a high-end server comprised of two main subsystems: the SC815TQ-R706WB 1U server cha

Page 14 - Manageability Engine (ME)

7-22SUPERSERVER 6018R-WTR(T) USER'S MANUALHigh Precision Event TimerSelect Enabled to activate the High Precision Event Timer (HPET) that produce

Page 15 - System Block Diagram

Chapter 7: BIOS7-23Intel TXT(LT-SX) Confi gurationThis feature indicates if the following hardware components support the Intel TXT (Trusted Execution

Page 16 - 1-5 Contacting Supermicro

7-24SUPERSERVER 6018R-WTR(T) USER'S MANUALRuntime Error Logging SupportChange this item to enable or disable runtime error logging. The options a

Page 17 - Server Installation

Chapter 7: BIOS7-257-5 IPMIUse this menu to confi gure Intelligent Platform Management Interface (IPMI) settings.System Event LogEnabling/Disabling Op

Page 18 - 2-4 Warnings and Precautions

7-26SUPERSERVER 6018R-WTR(T) USER'S MANUALWhen SEL is FullThis feature allows the user to decide what the BIOS should do when the system event lo

Page 19 - Rack Mounting Considerations

Chapter 7: BIOS7-277-6 BootThis menu allows the user to confi gure the following boot settings for the system.Set Boot Priorities1st Boot Device/2nd Bo

Page 20 - Reliable Ground

7-28SUPERSERVER 6018R-WTR(T) USER'S MANUALUSB Hard Disk Drive BBS PrioritiesThis submenu allows the user to specify the boot priority sequence o

Page 21 - Installing the Inner Rails

Chapter 7: BIOS7-29Password CheckThis item allows you to decide when the system should check for a password after it has been entered. Select Setup fo

Page 22 - Installing the Outer Rails

7-30SUPERSERVER 6018R-WTR(T) USER'S MANUALSave Changes and ResetWhen you have completed the system confi guration changes, select this option to s

Page 23

Chapter 7: BIOS7-31Boot OverrideThis feature allows the user to override the Boot Option Priorities setting in the Boot menu, and instead immediately

Page 24

1-2SUPERSERVER 6018R-WTR(T) USER'S MANUALNote: For your system to work properly, please follow the links below to download all necessary drivers/

Page 25

7-32SUPERSERVER 6018R-WTR(T) USER'S MANUALNotes

Page 26

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Page 27 - System Interface

A-2SUPERSERVER 6018R-WTR(T) USER'S MANUALNotes

Page 28 - 3-2 Control Panel Buttons

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® Xeon E5-2600v3 Series processorsNote: If using onl

Page 29 - 3-3 Control Panel LEDs

B-2SUPERSERVER 6018R-WTR(T) USER'S MANUALWeightGross (Bare Bone): 25 lbs (11.3 kg)System CoolingContains up to fi ve (5) 4-cm heavy-duty counter-r

Page 30 - 3-4 Hard Drive Carrier LEDs

B-3Appendix B: System Specifi cationsNotes

Page 31 - Chapter 4

B-4SUPERSERVER 6018R-WTR(T) USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will not be used in life

Page 32

Chapter 1: Introduction1-3PCI Expansion SlotsThe X10DRW-i(T) has one (1) SMC-proprietary PCI-E 3.0 x16 slot, one (1) SMC-proprietary PCI-E 3.0 x16+x16

Page 33

1-4SUPERSERVER 6018R-WTR(T) USER'S MANUALFront Control PanelThe chassis' control panel provides you with system monitoring and control. LEDs

Page 34 - Installation Instructions

Chapter 1: Introduction1-5Figure 1-1. Intel PCH-C612 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for deta

Page 35 - 250 V, 20 A

1-6SUPERSERVER 6018R-WTR(T) USER'S MANUAL1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131

Page 36 - Power Disconnection Warning

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6018R-

Page 37 - ﺔﻗﺎﻄﻟﺍ ﻞﺒﻗ

2-2SUPERSERVER 6018R-WTR(T) USER'S MANUALChoosing a Setup Location• Leave enough clearance in front of the rack to enable you to open the front d

Page 38 - Equipment Installation

Chapter 2: Server Installation2-3• Install the heaviest server components on the bottom of the rack fi rst, and then work up.• Use a regulating uninter

Page 39 - Restricted Area

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Page 40 - Battery Handling

2-4SUPERSERVER 6018R-WTR(T) USER'S MANUALCircuit OverloadingConsideration should be given to the connection of the equipment to the power supply

Page 41 - ﺔﻳﺭﺎﻄﺒﻟﺍ ﻝﺍﺪﺒﺘﺳﺍ

Chapter 2: Server Installation2-5Figure 2-1. Identifying the Sections of the Rack Rails (right side rail shown)2-5 Installing the System into a RackT

Page 42 - Redundant Power Supplies

2-6SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 2-2. Installing the Rack RailsInstalling the Outer RailsBegin by measuring the distance from the

Page 43 - Backplane Voltage

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached to

Page 44 - .הדובעה

2-8SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 2-5. Accessing the Inside of the System2-6 Checking the Serverboard SetupAfter you install the S

Page 45 - יצראה למשחה יקוח םואית

Chapter 2: Server Installation2-9Checking the Components1. You may have one or two processors already installed in the serverboard. Each processor ne

Page 46 - רצומה קוליס

2-10SUPERSERVER 6018R-WTR(T) USER'S MANUALNotes

Page 47 - ﻊﺑﺎﺻﻷﺍ ﻭﻲﻏﺍﺮﺒﻟﺍ ﺕﺎﻜﻔﻣ

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca

Page 48 - Power Cable and AC Adapter

3-2SUPERSERVER 6018R-WTR(T) USER'S MANUALUIDDepressing the UID (unit identifi er) button illuminates an LED on both the front and rear of the chas

Page 49 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

Chapter 3: System Interface3-33-3 Control Panel LEDsThe control panel located on the front of the SC815TQ-R706WB chassis has fi ve LEDs. These LEDs pr

Page 50

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Page 51 - Advanced Serverboard Setup

3-4SUPERSERVER 6018R-WTR(T) USER'S MANUALPowerIndicates power is being supplied to the system's power supply units. This LED should normally

Page 52 - 5-2 Connecting Cables

4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe f

Page 53 - Connecting the Control Panel

4-2SUPERSERVER 6018R-WTR(T) USER'S MANUALWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situat

Page 54 - 5-3 Rear I/O Ports

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에

Page 55 - Pull lever away

4-4SUPERSERVER 6018R-WTR(T) USER'S MANUALInstallation Instructions Warning!Read the installation instructions before connecting the system to the

Page 56 - WARNING!

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Page 57

4-6SUPERSERVER 6018R-WTR(T) USER'S MANUALPower Disconnection Warning Warning!The system must be disconnected from all sources of power and the po

Page 58

4-7Chapter 4: Warning Statements for AC SystemsWarnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von

Page 59 - 5-5 Installing Memory

4-8SUPERSERVER 6018R-WTR(T) USER'S MANUALEquipment Installation Warning!Only trained and qualifi ed personnel should be allowed to install, replac

Page 60 - DIMM Module Population Table

4-9Chapter 4: Warning Statements for AC SystemsRestricted Area Warning!This unit is intended for installation in restricted access areas. A restricted

Page 61

SUPERSERVER 6018R-WTR(T) USER'S MANUALivChapter 5: Advanced Serverboard SetupThis chapter provides detailed information on the X10DRW-i(T) server

Page 62 - 5-4 Serverboard Details

4-10SUPERSERVER 6018R-WTR(T) USER'S MANUALBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Repla

Page 63 - X10DRW-i(T) Connectors

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Page 64 - LED Description State Status

4-12SUPERSERVER 6018R-WTR(T) USER'S MANUALRedundant Power Supplies Warning!This unit might have more than one power supply connection. All connec

Page 65 - 5-7 Connector Defi nitions

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning!Hazardous voltage or energy is present on the backplane when the system is o

Page 66

4-14SUPERSERVER 6018R-WTR(T) USER'S MANUALComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with

Page 67

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Page 68

4-16SUPERSERVER 6018R-WTR(T) USER'S MANUALWarnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen

Page 69

4-17Chapter 4: Warning Statements for AC Systems!הרהזא יקלח תא םיריסמ רשאכ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפ

Page 70

4-18SUPERSERVER 6018R-WTR(T) USER'S MANUALPower Cable and AC Adapter Warning!When installing the product, use the provided or designated connect

Page 71 - 5-8 Jumper Settings

4-19Chapter 4: Warning Statements for AC Systems¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cabl

Page 72

vPrefaceNotes

Page 73 - Jumper Settings

4-20SUPERSERVER 6018R-WTR(T) USER'S MANUALWaarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels, stroomk

Page 74 - 5-9 Onboard LED Indicators

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable

Page 75 - 5-10 SATA Connections

5-2SUPERSERVER 6018R-WTR(T) USER'S MANUAL5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to th

Page 76 - 5-11 Installing Software

Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. Control Panel Header PinsPower ButtonOH/Fan Fail/PWR Fail LED)1NIC1 Link LEDReset Button2Power Fai

Page 77 - SuperDoctor 5

5-4SUPERSERVER 6018R-WTR(T) USER'S MANUAL5-3 Rear I/O PortsThe I/O ports are in conformance with the PC 99 specifi cation. See Figure 5-2 below f

Page 78

Chapter 5: Advanced Serverboard Setup5-51. There are two levers on the LGA2011 socket. First press and release the load lever labeled 'Open 1st&

Page 79 - 5-12 Serverboard Battery

5-6SUPERSERVER 6018R-WTR(T) USER'S MANUAL3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st

Page 80

Chapter 5: Advanced Serverboard Setup5-7Caution: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inse

Page 81 - Advanced Chassis Setup

5-8SUPERSERVER 6018R-WTR(T) USER'S MANUALInstalling and Removing a Passive CPU Heatsink1. Install the 1U passive CPU heatsink part number SNK-P0

Page 82 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-95-5 Installing MemoryCaution! Exercise extreme care when installing or removing DIMM modules to prevent any p

Page 83 - Optional Fan

viSUPERSERVER 6018R-WTR(T) USER'S MANUALTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 84 - Removing the Front Bezel

5-10SUPERSERVER 6018R-WTR(T) USER'S MANUALDIMM Module Population TableFollow the tables below when installing memory.Processors and their Corresp

Page 85 - Hard Drive Installation

Chapter 5: Advanced Serverboard Setup5-11Populating RDIMM/LRDIMM Memory Modules Intel E5-2600v3 Series Processor Memory SupportType Ranks Per DIMM &am

Page 86 - DVD-ROM Drive Installation

5-12SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 5-5. X10DRW-i(T) Layout5-4 Serverboard DetailsS-SGPIOI-SGPIO2I-SGPIO1JIPMB1SAN MACIPMI CODEJBAT1

Page 87 - 6-5 Power Supply

Chapter 5: Advanced Serverboard Setup5-13X10DRW-i(T) ConnectorsConnectors DescriptionAOM Slot (J35) PCI-E 3.0 x16 Add-On-Module (AOM) slot for the mez

Page 88

5-14SUPERSERVER 6018R-WTR(T) USER'S MANUALX10DRW-i(T) JumpersJumper Description Default SettingJBT1 Clear CMOS See Chapter 3JI2C1/JI2C2 SMB to PC

Page 89 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-155-7 Connector Defi nitions Power Connectors A 24-pin main power supply connector (JPWR1), and two 8-pin CPU po

Page 90 - 7-2 Main Setup

5-16SUPERSERVER 6018R-WTR(T) USER'S MANUALNIC1/NIC2 LED IndicatorsThe NIC (Network Interface Controller) LED connection for LAN Port 1 is located

Page 91 - Boot Feature

Chapter 5: Advanced Serverboard Setup5-17Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for p

Page 92

5-18SUPERSERVER 6018R-WTR(T) USER'S MANUALUniversal Serial Bus (USB)Four USB 3.0 ports (USB 0/1, USB 2/3) are located on the I/O backpanel. In ad

Page 93 - CPU Confi guration

Chapter 5: Advanced Serverboard Setup5-19Unit Identifi er Switch/UID LED IndicatorA Unit Identifi er (UID) switch is located on the I/O backplane, and t

Page 94

viiTable of ContentsInstalling the Outer Rails ... 2-6Installing the Ser

Page 95

5-20SUPERSERVER 6018R-WTR(T) USER'S MANUALS-SGPIO and I-SGPIO 1/2 HeadersThree SGPIO (Serial Link General Purpose Input/Output) headers are locat

Page 96

Chapter 5: Advanced Serverboard Setup5-215-8 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Page 97 - Integrated IO Confi guration

5-22SUPERSERVER 6018R-WTR(T) USER'S MANUALWatch Dog Enable/DisableJumper Settings (JWD1)Jumper Setting Defi nitionPins 1-2 ResetPins 2-3 NMIOp

Page 98 - QPI Confi guration

Chapter 5: Advanced Serverboard Setup5-23I2C to PCI-EJumper SettingJumper Setting Defi nitionPins 1-2 EnabledPins 2-3 Disabled (Default)ME Mode Sel

Page 99 - DIMM Information

5-24SUPERSERVER 6018R-WTR(T) USER'S MANUALIPMI Dedicated LAN LEDsIn addition to LAN 1/LAN 2, an IPMI- dedicated LAN is located on the I/O Backpla

Page 100

Chapter 5: Advanced Serverboard Setup5-25Note: Refer to Page 2-21 for information on the rear UID LED (LED1).Onboard Power LED An Onboard Power LED is

Page 101 - South Bridge

5-26SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 5-6. Driver/Tool Installation Display Screen5-11 Installing SoftwareThe Supermicro ftp site cont

Page 102 - SATA Confi guration

Chapter 5: Advanced Serverboard Setup5-27Note: Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the compu

Page 103 - PCIe/PCI/PnP Confi guration

5-28SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 5-8. SuperDoctor 5 Interface Display Screen (Remote Control)Note: The SuperDoctor 5 program and

Page 104

Chapter 5: Advanced Serverboard Setup5-295-12 Serverboard BatteryCaution: There is a danger of explosion if the onboard battery is installed upside do

Page 105 - COM 1 Confi guration

viiiSUPERSERVER 6018R-WTR(T) USER'S MANUALChapter 5 Advanced Serverboard Setup5-1 Handling the Serverboard ...

Page 106 - Console Redirection Settings

5-30SUPERSERVER 6018R-WTR(T) USER'S MANUALNotes

Page 107

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Page 108

6-2SUPERSERVER 6018R-WTR(T) USER'S MANUALFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the

Page 109 - ACPI Settings

Chapter 6: Advanced Chassis Setup6-3System Fan FailureFan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining

Page 110 - • ME Version

6-4SUPERSERVER 6018R-WTR(T) USER'S MANUALAccessing the Drive BaysHard Drives: Because of their hotswap capability, you do not need to access the

Page 111 - 7-4 Event Logs

Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr

Page 112

6-6SUPERSERVER 6018R-WTR(T) USER'S MANUALInstalling/Removing a Hard Drive1. To remove a carrier, push the release button located beside the driv

Page 113 - 7-5 IPMI

Chapter 6: Advanced Chassis Setup6-7Removing the Chassis Cover1. Grasp the two handles on either side and pull the unit straight out until it locks (

Page 114 - BMC Network Confi guration

6-8SUPERSERVER 6018R-WTR(T) USER'S MANUALReplacing the Power SupplyYou do not need to shut down the system to replace a power supply module. The

Page 115 - 7-6 Boot

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup utility for the X10DRW-i(T) It also provides the instruct

Page 116 - 7-7 Security

Table of Contentsix5-8 Jumper Settings ... 5-21Explanation of

Page 117 - 7-8 Save & Exit

7-2SUPERSERVER 6018R-WTR(T) USER'S MANUALHow To Change the Confi guration DataThe confi guration data that determines the system parameters may be

Page 118

Chapter 7: BIOS7-3Memory InformationTotal MemoryThis displays the amount of memory that is available in the system.7-3 Advanced Setup Confi gurations

Page 119 - Boot Override

7-4SUPERSERVER 6018R-WTR(T) USER'S MANUALBootup Num-LockUse this feature to set the Power-on state for the Numlock key. The options are Off and O

Page 120

Chapter 7: BIOS7-5CPU Confi gurationThis submenu displays the information of the CPU as detected by the BIOS. It also allows the user to confi gure the

Page 121 - BIOS Error Beep Codes

7-6SUPERSERVER 6018R-WTR(T) USER'S MANUALRTID (Record Types IDs)This feature displays the total number of Record Type IDs for local and remote po

Page 122

Chapter 7: BIOS7-7DCU Streamer Prefetcher (Available when supported by the CPU)Select Enabled to support Data Cache Unite (DCU) prefetch to speed up d

Page 123 - System Specifi cations

7-8SUPERSERVER 6018R-WTR(T) USER'S MANUALC1E Support (Available when Power Technology is set to Custom)Select Enabled to enable Enhanced C1 Power

Page 124

Chapter 7: BIOS7-9Long Duration MaintainedThis item displays the period of time (in seconds) during which long duration power is maintained. The defau

Page 125

7-10SUPERSERVER 6018R-WTR(T) USER'S MANUALIntel® I/OATSelect Enabled to enable Intel I/OAT (I/O Acceleration Technology), which will significantl

Page 126

Chapter 7: BIOS7-11QPI (Quick Path Interconnect) Link Speed ModeUse this feature to select data transfer speed for QPI Link connections. The options a