®SUPERSERVER® 5028R-WR SUPERUSER’S MANUAL 1.0
1-2SUPERSERVER 5028R-WR User's Manual1-2 Motherboard FeaturesThe SuperServer 5028R-WR is built around the X10SRW-F, a single processor motherboa
7-18SUPERSERVER 5028R-WR User's ManualEHCI2Select Enabled to enable EHCI (Enhanced Host Controller Interface) support on USB 2.0 connector #2 (-a
Chapter 7: BIOS7-19SATA Port 0~ Port 5This item displays the information detected on the installed SATA drive on the particular SATA port.•Model numb
7-20SUPERSERVER 5028R-WR User's Manual*If the item above "Congure SATA as" is set to RAID, the following items will display:Support Ag
Chapter 7: BIOS7-21sSATA CongurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of the SATA devices that are supp
7-22SUPERSERVER 5028R-WR User's ManualsSATA Port 0 ~ Port 3 Spin Up DeviceOn an edge detect from 0 to 1, set this item to allow the PCH to start
Chapter 7: BIOS7-23sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabled and Enabled.sSATA Port 0
7-24SUPERSERVER 5028R-WR User's Manual•PCI Latency TimerPCI AER (Advanced Error-Reporting) SupportUse this item to congure the PCI-X latency ti
Chapter 7: BIOS7-25on the system conguration. Select Disabled to disable ASPM support. The options are Disabled and Auto.Warning: Enabling ASPM suppo
7-26SUPERSERVER 5028R-WR User's ManualSuper IO Conguration Super IO Chip AST2400Serial Port 1 Conguration/Serial Port 2 CongurationSerial Po
Chapter 7: BIOS7-27COM1 Console RedirectionTerminal TypeThis feature allows the user to select the target terminal emulation type for Con-sole Redire
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe 5028R-WR is built upon the SC825TQ-R500WB chassis. Details on the chassis and on servicing p
7-28SUPERSERVER 5028R-WR User's ManualRecorder ModeSelect Enabled to capture the data displayed on a terminal and send it as text messages to a r
Chapter 7: BIOS7-29Bits Per secondUse this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the sam
7-30SUPERSERVER 5028R-WR User's ManualLegacy OS Redirection ResolutionUse this feature to select the number of rows and columns used in Console
Chapter 7: BIOS7-31Bits Per SecondThis item sets the transmission speed for a serial port used in Console Redirec-tion. Make sure that the same speed
7-32SUPERSERVER 5028R-WR User's ManualACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) plat-fo
Chapter 7: BIOS7-337-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log SettingsThis feature allows the user to co
7-34SUPERSERVER 5028R-WR User's ManualErasing SettingsErase Event LogSelect Enabled to erase all error events in the SMBIOS (System Management BI
Chapter 7: BIOS7-357-5 IPMIUse this feature to congure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionTh
7-36SUPERSERVER 5028R-WR User's ManualWhen SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem event lo
Chapter 7: BIOS7-37Gateway IP AddressThis item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i
1-4SUPERSERVER 5028R-WR User's ManualFigure 1-1. Intel C612 Express Chipset: System Block DiagramNote: This is a general block diagram. Please
7-38SUPERSERVER 5028R-WR User's Manual7-6 Security SettingsThis menu allows the user to congure the following security settings for
Chapter 7: BIOS7-397-7 Boot SettingsUse this feature to congure Boot Settings:Setup Prompt TimeoutUse this item to indicate the length of time (the
7-40SUPERSERVER 5028R-WR User's Manual•Dual Boot Order #8•Dual Boot Order #9•Dual Boot Order #10•Dual Boot Order #11•Dual Boot Order #12•Du
Chapter 7: BIOS7-417-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard Cha
7-42SUPERSERVER 5028R-WR User's ManualSave As User DefaultsTo set this feature, select Save as User Defaults from the Exit menu and press <En-
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed at each syste
A-2SUPERSERVER 5028R-WR User's ManualNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle Intel E5-2600/E5-1600 v3 Series processor in an LGA2011 socket (S
B-2SUPERSERVER 5028R-WR User's ManualSystem CoolingThree 8-cm system cooling fansSystem Input RequirementsAC Input Voltage: 100-240V AC auto-rang
B-3Appendix B: System SpecicationsNotes
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
B-4SUPERSERVER 5028R-WR User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life supp
1-6SUPERSERVER 5028R-WR User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5028
2-2SUPERSERVER 5028R-WR User's Manual•This product is not suitable for use with visual display work place devices acccording to §2 of the the Ge
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 5028R-WR User's Manual2-5 Installing the System into a RackThis section provides information on installing the SC825 chassis into
Chapter 2: Server Installation2-5Figure 2-1: Separating the Rack Rails screw the handles the outer rails for secure purpose if necessaryF.ABLECOMDATE:
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 5028R-WR User's ManualOuter Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC825
Chapter 2: Server Installation2-7screw the handles the outer rails for secure purpose if necessaryF.ABLECOMDATE:2008/08/14REV:2SCREWSCREWCOMPLETE12Fig
2-8SUPERSERVER 5028R-WR User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carri
SUPERSERVER 5028R-WR User's Manual3-2123-3 Control Panel LEDsThe control panel located on the front of the chassis has several LEDs. These LEDs
Chapter 3: System Interface3-3HDDOn the SuperServer 5028R-WR, this LED indicates hard drive and/or DVD-ROM drive activity when ashing.PowerIndicates
SUPERSERVER 5028R-WR User's Manual3-4Notes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
4-2SUPERSERVER 5028R-WR User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer Situat
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-4SUPERSERVER 5028R-WR User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the pow
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 5028R-WR User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源コードは
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 5028R-WR User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qualied
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi
4-10SUPERSERVER 5028R-WR User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Replace t
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 5028R-WR User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom z
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
SUPERSERVER 5028R-WR User's ManualivChapter 5: Advanced Motherboard SetupChapter 5 provides detailed information on the X10SRW-F motherboard, in
4-14SUPERSERVER 5028R-WR User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with loca
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 5028R-WR User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 5028R-WR User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables and AC
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 5028R-WR User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cab
5-2SUPERSERVER 5028R-WR User's Manual5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the b
Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. Control Panel Header Pins5-3 Rear I/O PortsSee Figure 5-2 below for the descriptions of the vario
NotesPrefacev
5-4SUPERSERVER 5028R-WR User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled 'Open 1s
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSERVER 5028R-WR User's Manual7. With the CPU in the socket, in-spect the four corners of the CPU to make sure that they are ush with th
Chapter 5: Advanced Serverboard Setup5-7Figure 5-3. Installing the HeatsinkRemoving the HeatsinkCaution: Removing the CPU or the heatsink is not rec
5-8SUPERSERVER 5028R-WR User's ManualMemory SupportThe X10SRW-F supports up to 512 GB of ECC/non-ECC Load-Reduced (LRDIMM), up to 256 GB of ECC R
Chapter 5: Advanced Serverboard Setup5-9DIMM Module Population TableFollow the tables below when installing memory.Memory Population GuidelinesPlease
5-10SUPERSERVER 5028R-WR User's ManualNotes:Using DDR4 DIMMs with different operating frequencies is not allowed. Be sure to use memory modules o
Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCIe Add-On CardsThe 5028R-WR can accommodate four standard size PCI-E 3.0 x8 and one low-prole,
5-12SUPERSERVER 5028R-WR User's ManualFigure 5-6. X10SRW-F Layout5-7 Serverboard DetailsIPMI CODE41231111BIOS LICENSEDESIGNED IN USAMAC CODEX10
Chapter 5: Advanced Serverboard Setup5-13Notes• " " indicates the location of "Pin 1".•Jumpers not indicated are for test purpo
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-14SUPERSERVER 5028R-WR User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switch
Chapter 5: Advanced Serverboard Setup5-15Overheat (OH)/Fan Fail/PWR Fail/UID LEDConnect an LED cable to pins 7 and 8 of Front Control Panel to use the
5-16SUPERSERVER 5028R-WR User's ManualFan HeadersThere are six fan headers on the serverboard, all of which are 4-pin fans (Fan 1-2, Fan 4-7). Pi
Chapter 5: Advanced Serverboard Setup5-17Ethernet PortsTwo Ethernet ports (LAN1/LAN2) are located on the rear I/O backpanel. In addition, an dedicated
5-18SUPERSERVER 5028R-WR User's ManualT-SGPIO HeaderThree SGPIO (Serial General Pur-pose Input/Output) headers are used to communicate with the e
Chapter 5: Advanced Serverboard Setup5-19DOM Power ConnectorThe power connectors (JSD1, JSD2) provide 5V power to a solid state DOM storage device con
5-20SUPERSERVER 5028R-WR User's ManualStandby Power HeaderThe +5V Standby Power header is lo-cated at JSTBY1. See the table on the right for pin
Chapter 5: Advanced Serverboard Setup5-21LAN Enable/DisableUse JPL1 and JPL2 to enable/disable LAN ports 1/2. See the table on the right for jumper se
5-22SUPERSERVER 5028R-WR User's Manual5-10 Onboard IndicatorsLAN LEDsThe Ethernet ports have two LEDs. On each port, the yellow LED ashes to in
Chapter 5: Advanced Serverboard Setup5-23BMC Heartbeat LEDA BMC Heartbeat LED is located at LEDM1. When blinking, the BMC is functioning normally.BMC
vii3-3 Control Panel LEDs ... 3-2Power Fail ...
5-24SUPERSERVER 5028R-WR User's Manual5-11 SATA PortsSATA PortPin DenitionsPin# Denition Pin Denition1 Ground 2 TXP3 TXN 4 G
Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
5-26SUPERSERVER 5028R-WR User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based inter
Chapter 5: Advanced Serverboard Setup5-275-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged
5-28SUPERSERVER 5028R-WR User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-
6-2SUPERSERVER 5028R-WR User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front of the ch
Chapter 6: Advanced Chassis Setup6-36-4 Drive Bay Installation/RemovalAccessing the Drive BaysSATA Drives: You do not need to access the inside of th
6-4SUPERSERVER 5028R-WR User's ManualFigure 6-3. Removing a SATA Drive CarrierRelease ButtonHandleFigure 6-4. Mounting a SATA Drive in a CarrierI
Chapter 6: Advanced Chassis Setup6-5Hard Drive BackplaneThe hard drives plug into a backplane that provides power, drive ID and bus termi-nation. A RA
viiiSUPERSERVER 5028R-WR User's Manual5-6 Adding PCIe Add-On Cards ...5-
6-6SUPERSERVER 5028R-WR User's Manual6-6 System FansThree 8-cm hot-swap fans provide the cooling for the system. It is very important that the c
Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Removing System Cooling Fans
6-8SUPERSERVER 5028R-WR User's Manual6-7 Power SupplyThe SuperServer 5028R-WR has a 500 watt redundant power supply consisting of two power modu
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10SRW-F. The ROM BIOS is stored in a F
7-2SUPERSERVER 5028R-WR User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory tes
Chapter 7: BIOS7-3System Date/System Time Use this option to change the system date and time. Highlight System Date or System Time using the arrow key
7-4SUPERSERVER 5028R-WR User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <Enter> to acc
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur
7-6SUPERSERVER 5028R-WR User's ManualRestore on AC Power LossUse this feature to set the power state after a power outage. Select Power-Off for t
Chapter 7: BIOS7-7Hyper-ThreadingSelect Enable to use Intel Hyper-Threading Technology to enhance CPU perfor-mance. The options are Enable and Disable
Chapter 1 Introduction1-1 OverviewThe SuperServer 5028R-WR is comprised of two main subsystems: the SC825TQ-R500WB 2U chassis and the X10SRW-F mothe
7-8SUPERSERVER 5028R-WR User's ManualDCU IP PrefetcherIf this item is set to Enable, the IP prefetcher in the DCU (Data Cache Unit) will prefetch
Chapter 7: BIOS7-9Advanced Power Management CongurationPower TechnologySelect Energy Efcient to support power-saving mode. Select Custom to custom-
7-10SUPERSERVER 5028R-WR User's ManualCPU C6 Report (Available when Power Technology is set to Custom)Select Enable to allow the BIOS to report t
Chapter 7: BIOS7-11Short Duration Power Limit EnableSelect Enable to support Short Duration Power Limit (Power Limit 2). The options are Enable and Di
7-12SUPERSERVER 5028R-WR User's ManualPORT 2A Link SpeedUse this item to congure the link speed of a PCI-E port specied by the user. The option
Chapter 7: BIOS7-13 Intel VT for Directed I/O (VT-d)Intel VT for Direct I/O (VT-d)Intel® VT for Directed I/O (VT-d)Select Enable to use Intel Virtual
7-14SUPERSERVER 5028R-WR User's ManualLink Speed ModeUse this item to select the data transfer speed for QPI Link connections. The options are Fa
Chapter 7: BIOS7-15DRAM RAPL (Running Average Power Limit) BaselineUse this feature to set the run-time power-limit baseline for DRAM modules. The opt
7-16SUPERSERVER 5028R-WR User's ManualMemory RAS (Reliability_Availability_Serviceability) Conguration Use this submenu to congure the followi
Chapter 7: BIOS7-17South BridgeThe following South Bridge information will display:\•USB Conguration•USB Module Version•USB DevicesLegacy USB Sup
Comments to this Manuals