Page 1 - SUPER

®SUPERSERVER1027R-WC1R1027R-WC1RT SUPERUSER’S MANUAL1.0

Page 2 - Manual Revision 1.0

1-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual1-2 Serverboard FeaturesThe SuperServer 1027R-WC1R/1027R-WC1RT is built around the X9DRW-CF31/

Page 3 - Manual Organization

7-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMaximum Read RequestSelect Auto to allow the system BIOS to automatically set the maximum Rea

Page 4

Chapter 7: BIOS7-17COM Confi gurationSerial PortSelect Enabled to enable a serial port specifi ed by the user. The options are En-abled and Disabled.De

Page 5

7-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSerial Port 2 AttributeUse this feature to select the attribute for serial port 2. The option

Page 6 - Table of Contents

Chapter 7: BIOS7-19is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a par

Page 7

7-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manualdisabled before the OS is initialized. When this feature is set to Always Enable, Legacy Cons

Page 8

Chapter 7: BIOS7-21Data Bits, Parity, Stop BitsThe status of these features is displayed.ACPI SettingUse this feature to confi gure Advanced Confi gura

Page 9 - Introduction

7-22SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualPending Operation: This item displays the status of a pending operation.Current Status Inform

Page 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-23Intel ME Subsystem Confi gurationThis feature displays the following ME Subsystem Confi guration settings.• ME BIOS Interface Versio

Page 11 - 1-3 Server Chassis Features

7-24SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory Correctable Error ThresholdThis feature allows the user to enter the threshold value f

Page 12 - System Block Diagram

Chapter 7: BIOS7-257-5 IPMIUse this feature to confi gure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionThis item

Page 13 - 1-4 Contacting Supermicro

1-3Chapter 1: IntroductionRear I/O PortsPorts on the I/O backplane include a VGA port, four USB 2.0 ports, two gigabit Ethernet ports and one dedicate

Page 14

7-26SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWhen SEL is FullThis feature allows the user to decide what the BIOS should do when the syste

Page 15 - Server Installation

Chapter 7: BIOS7-277-6 BootThis submenu allows the user to confi gure the following boot settings for the system.Set Boot PriorityUse these items to

Page 16 - 2-4 Warnings and Precautions

7-28SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNetwork Device BBS PrioritiesThis item is used to select the boot device priority sequence f

Page 17 - Rack Mounting Considerations

Chapter 7: BIOS7-297-8 Save & ExitThis submenu allows the user to confi gure the Save and Exit settings for the system.Discard Changes and Exit S

Page 18 - Extensions

7-30SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualDiscard ChangesSelect this feature and press <Enter> to discard all the changes and ret

Page 19 - Inner Rail Extension

A-1Appendix A: BIOS POST Error CodesBIOS Error Beep CodesBeep Code/LED Error Message Description1 beep Refresh Ready to boot5 short beeps + 1 long bee

Page 20 - Outer Rails

A-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes

Page 21

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® Xeon E5-2600 v1/v2 Series processorsNote: Please r

Page 22

B-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSystem CoolingSix 4-cm counter-rotating fansSystem Input RequirementsAC Input Voltage: 100V -

Page 23

B-3Appendix B: System Specifi cationsNotes

Page 24

1-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 1-1. Intel C602J Chipset: System Block DiagramNote: This is a general block diagram. P

Page 25 - System Interface

B-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be use

Page 26 - 3-3 Control Panel LEDs

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Page 27

1-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes

Page 28 - 3-4 Hard Drive Carrier LEDs

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 1027R-

Page 29 - Chapter 4

2-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual• This product is for installation only in a Restricted Access Location (dedicated equipment r

Page 30

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Page 31 - ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ

2-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual2-5 Rack Mounting InstructionsThis section provides information on installing the SC116 chass

Page 32 - Installation Instructions

Chapter 2: Server Installation2-5Figure 2-2. Identifying the Sections of the Rack Rails (right side rail shown)Inner Rail ExtensionThe SC116 chassis

Page 33 - Circuit Breaker

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 34 - Power Disconnection Warning

2-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualOuter RailsInstalling the Outer Rails to the Rack1. Attach the shorter outer rail to the outs

Page 35 - ילמשח קותינ ינפמ הרהזא

Chapter 2: Server Installation2-7Figure 2-4. Installing the Outer Rails to the Server Rack121313Note: fi gures are for illustrative purposes only. Alw

Page 36 - Equipment Installation

2-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 2-5. Installing the Rack RailsInstalling the Chassis into a Rack1. Confi rm that chassi

Page 37 - Restricted Area

Chapter 2: Server Installation2-9Installing the Chassis into a Telco rackTo install the chassis into a Telco or post-style rack, use two L-shaped brac

Page 38 - Battery Handling

2-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 2-6. Installing the Chassis into a Telco RackNote: fi gures are for illustrative purpo

Page 39

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel and on the drive carriers that provide

Page 40 - Redundant Power Supplies

3-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualUIDDepressing the UID (Unit Identifi er) button illuminates an LED on both the front and rear o

Page 41 - Backplane Voltage

Chapter 3: System Interface3-3HDDIndicates SAS/SATA channel activity and/or DVD-ROM drive activity when fl ashing. NIC2Indicates network activity on GL

Page 42

3-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual3-4 Hard Drive Carrier LEDsThe SC116AC chassis supports the use of 10 SAS/SATA drives. SAS/SA

Page 43 - Product Disposal

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Page 44 - רצומה קוליס

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 45

4-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in ei

Page 46 - Power Cable and AC Adapter

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Page 47 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

4-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the sys

Page 48

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Page 49 - Advanced Serverboard Setup

4-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソー

Page 50 - • Control Panel cable (JF1)

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Page 51 - 5-3 Rear I/O Ports

4-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained

Page 52 - OPEN 1st

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th

Page 53 - WARNING!

4-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrec

Page 54

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Page 55

SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X9DRW-CF31

Page 56 - 5-5 Installing Memory

4-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einhe

Page 57 - DIMM Module Population Table

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Page 58

4-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must co

Page 59 - 5-6 Adding PCI Add-On Cards

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Page 60 - 5-7 Serverboard Details

4-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstem

Page 61

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Page 62 - 5-8 Connector Defi nitions

4-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual Warning!When installing the product, use the provided or designated connection cables, power

Page 63

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Page 64

4-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes

Page 65 - Pin # Defi nition

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable

Page 66

NotesPrefacev

Page 67

5-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the ca

Page 68 - 5-9 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. Control Panel Header Pins5-3 Rear I/O PortsSee Figure 5-2 below for the colors and locations of t

Page 69

5-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled

Page 70

Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,

Page 71 - 5-10 Onboard Indicators

5-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual7. With the CPU in the socket, in-spect the four corners of the CPU to make sure that they ar

Page 72 - 5-11 SATA and SAS Ports

Chapter 5: Advanced Serverboard Setup5-7Figure 5-3. Installing the HeatsinksFigure 5-4. Securing a HeatsinkNote: be aware that the heatsink for CPU1

Page 73 - 5-12 Installing Software

5-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory SupportThe X9DRW-CF31/CTF31 supports up to 1024 GB of ECC Load-Reduced (LRDIMM), up to

Page 74 - SuperDoctor® 5

Chapter 5: Advanced Serverboard Setup5-9DIMM Module Population TableFollow the tables below when installing memory.Processors and their Corresponding

Page 75 - 5-13 Onboard Battery

5-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes:Using DDR3 DIMMs with different operating frequencies is not allowed. All channels in a

Page 76

Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI Add-On CardsThe 1027R-WC1R/1027R-WC1RT can accommodate two full-height, half-length PCI-E 3.0

Page 77 - Advanced Chassis Setup

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 78 - 6-2 Control Panel

5-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 5-6. X9DRW-CF31/CTF31 Layout5-7 Serverboard DetailsNotes• " " indicates t

Page 79 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-13Jumper Description Default Setting JBT1 Clear CMOS See Section 5-9JI2C1/JI2C2 SMB to PCI-E Slots Pins 2-3 (No

Page 80

5-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the

Page 81 - Hard Drive Installation

Chapter 5: Advanced Serverboard Setup5-15Overheat (OH)/Fan Fail/PWR Fail/UID LEDConnect an LED cable to pins 7 and 8 of Front Control Panel to use the

Page 82

5-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFan HeadersThere are six fan headers on the serverboard, all of which are 4-pin fans (Fan 1-F

Page 83

Chapter 5: Advanced Serverboard Setup5-17Ethernet PortsTwo Ethernet ports are located on the I/O backplane. LAN ports 1/2 support gigabit LAN connecti

Page 84 - 6-5 Power Supply

5-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualT-SGPIO HeaderThe SGPIO (Serial General Purpose Input/Output) header is used to com-municate

Page 85 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-19DOM Power ConnectorA power connector for SATA DOM (Disk On Module) devices is located at JSD1. Connect an app

Page 86 - 7-2 Main Setup

5-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualStandby Power HeaderThe +5V Standby Power header is lo-cated at JSTBY1. See the table on the

Page 87 - Boot Features

Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con

Page 88 - CPU Confi guration

vii3-2 Control Panel Buttons ... 3-1Power ...

Page 89

5-22SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualBMC Enable Jumper JPB1 allows you to enable the embedded the Winbond WPCM 450 BMC (Baseboard

Page 90

Chapter 5: Advanced Serverboard Setup5-235-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,

Page 91

5-24SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual5-11 SATA and SAS PortsSATA PortPin Defi nitionsPin# Defi nition Pin Defi niti

Page 92

Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.s

Page 93 - Integrated IO Confi guration

5-26SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or w

Page 94 - QPI Confi guration

Chapter 5: Advanced Serverboard Setup5-275-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged b

Page 95 - DIMM Information

5-28SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes

Page 96

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 97 - South Bridge Confi guration

6-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the fr

Page 98 - SATA Confi guration

Chapter 6: Advanced Chassis Setup6-36-3 System FansIt is very important that the chassis top cover is properly installed and making a good seal in ord

Page 99 - PCIe/PCI/PnP Confi guration

viiiSUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory Support ...

Page 100 - Super IO Confi guration

6-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 6-2. Replacing a System Fan13

Page 101 - COM Confi guration

Chapter 6: Advanced Chassis Setup6-5Checking the Airfl owCheck the Airfl ow1. Make sure there are no objects obstructing the airfl ow in and out of the

Page 102 - • COM 1 and SOL

6-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual4. Insert the drive carrier into its bay, keeping the carrier oriented so that the hard drive

Page 103

Chapter 6: Advanced Chassis Setup6-7Figure 6-4. Removing a Hard Drive1112Caution: Use caution when working around the hard drive backplane. Do not to

Page 104

6-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual6-5 Power SupplyThe SC116 chassis comes equipped with two redundant 700W-750W power sup-plies.

Page 105 - ACPI Setting

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X9DRW-CF31/X9DRW-CTF31. It also provides

Page 106 - TPM Enable Status

7-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual7-2 Main SetupWhen you fi rst enter the AMI BIOS setup utility, you will enter the Main setup

Page 107 - • ME Version

Chapter 7: BIOS7-37-3 Advanced Setup Confi gurationsUse the arrow keys to select Advanced Setup and press <Enter> to access the following subme

Page 108

7-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualInterrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk feature.

Page 109 - 7-5 IPMI

Chapter 7: BIOS7-5• Type of CPU• CPU Signature• Microcode Patch• CPU Stepping• Maximum CPU Speed• Minimum CPU Speed• Processor Cores• Intel HT (Hyper-

Page 110 - BMC Network Confi guration

Chapter 1 Introduction1-1 OverviewThe SuperServer 1027R-WC1R/1027R-WC1RT is comprised of two main sub-systems: the SC116AC-R700WB 1U chassis and the X

Page 111 - 7-6 Boot

7-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manualapplications that rely on direct access to the system memory. The options are Optimal and Alte

Page 112 - • 1st Boot Device

Chapter 7: BIOS7-7DCU IP PrefetcherSelect Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch IP addresses to improve networ

Page 113 - 7-8 Save & Exit

7-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualC1E (Available when Power Technology is set to Custom)Select Enabled to enable Enhanced C1 Pow

Page 114 - • UEFI: Built-in EFI Shell

Chapter 7: BIOS7-9Long Duration MaintainedThis item displays the period of time in seconds during which long duration power is maintained.Recommended

Page 115 - BIOS Error Beep Codes

7-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualDCA SupportSelect Enabled to use Intel's DCA (Direct Cache Access) Technology to improve

Page 116

Chapter 7: BIOS7-11MesegEnSelect Enabled for Message support. The options are Enabled and Disabled.QPI (Quick Path Interconnect) Link Speed ModeUse th

Page 117 - System Specifi cations

7-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualCPU Socket 2 DIMM InformationP2-DIMME1/P2-DIMME2/P2-DIMMF1/P2-DIMMF2/P2-DIMMG1/P2-DIMMG2/P2-D

Page 118

Chapter 7: BIOS7-13source). Memory is updated as well. Select Enabled to use Demand Scrubbing for ECC memory correction. The options are Enabled and D

Page 119

7-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSelect Enabled to support legacy USB devices. Select Auto to disable legacy sup-port if USB d

Page 120

Chapter 7: BIOS7-15Port 0~3 Hot PlugSelect Enabled to enable hot-plug support for a particular port, which will allow the user to change a hardware co