®SUPERSERVER1027R-WC1R1027R-WC1RT SUPERUSER’S MANUAL1.0
1-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual1-2 Serverboard FeaturesThe SuperServer 1027R-WC1R/1027R-WC1RT is built around the X9DRW-CF31/
7-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMaximum Read RequestSelect Auto to allow the system BIOS to automatically set the maximum Rea
Chapter 7: BIOS7-17COM Confi gurationSerial PortSelect Enabled to enable a serial port specifi ed by the user. The options are En-abled and Disabled.De
7-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSerial Port 2 AttributeUse this feature to select the attribute for serial port 2. The option
Chapter 7: BIOS7-19is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a par
7-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manualdisabled before the OS is initialized. When this feature is set to Always Enable, Legacy Cons
Chapter 7: BIOS7-21Data Bits, Parity, Stop BitsThe status of these features is displayed.ACPI SettingUse this feature to confi gure Advanced Confi gura
7-22SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualPending Operation: This item displays the status of a pending operation.Current Status Inform
Chapter 7: BIOS7-23Intel ME Subsystem Confi gurationThis feature displays the following ME Subsystem Confi guration settings.• ME BIOS Interface Versio
7-24SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory Correctable Error ThresholdThis feature allows the user to enter the threshold value f
Chapter 7: BIOS7-257-5 IPMIUse this feature to confi gure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionThis item
1-3Chapter 1: IntroductionRear I/O PortsPorts on the I/O backplane include a VGA port, four USB 2.0 ports, two gigabit Ethernet ports and one dedicate
7-26SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWhen SEL is FullThis feature allows the user to decide what the BIOS should do when the syste
Chapter 7: BIOS7-277-6 BootThis submenu allows the user to confi gure the following boot settings for the system.Set Boot PriorityUse these items to
7-28SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNetwork Device BBS PrioritiesThis item is used to select the boot device priority sequence f
Chapter 7: BIOS7-297-8 Save & ExitThis submenu allows the user to confi gure the Save and Exit settings for the system.Discard Changes and Exit S
7-30SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualDiscard ChangesSelect this feature and press <Enter> to discard all the changes and ret
A-1Appendix A: BIOS POST Error CodesBIOS Error Beep CodesBeep Code/LED Error Message Description1 beep Refresh Ready to boot5 short beeps + 1 long bee
A-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® Xeon E5-2600 v1/v2 Series processorsNote: Please r
B-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSystem CoolingSix 4-cm counter-rotating fansSystem Input RequirementsAC Input Voltage: 100V -
B-3Appendix B: System Specifi cationsNotes
1-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 1-1. Intel C602J Chipset: System Block DiagramNote: This is a general block diagram. P
B-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be use
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
1-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 1027R-
2-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual• This product is for installation only in a Restricted Access Location (dedicated equipment r
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual2-5 Rack Mounting InstructionsThis section provides information on installing the SC116 chass
Chapter 2: Server Installation2-5Figure 2-2. Identifying the Sections of the Rack Rails (right side rail shown)Inner Rail ExtensionThe SC116 chassis
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualOuter RailsInstalling the Outer Rails to the Rack1. Attach the shorter outer rail to the outs
Chapter 2: Server Installation2-7Figure 2-4. Installing the Outer Rails to the Server Rack121313Note: fi gures are for illustrative purposes only. Alw
2-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 2-5. Installing the Rack RailsInstalling the Chassis into a Rack1. Confi rm that chassi
Chapter 2: Server Installation2-9Installing the Chassis into a Telco rackTo install the chassis into a Telco or post-style rack, use two L-shaped brac
2-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 2-6. Installing the Chassis into a Telco RackNote: fi gures are for illustrative purpo
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel and on the drive carriers that provide
3-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualUIDDepressing the UID (Unit Identifi er) button illuminates an LED on both the front and rear o
Chapter 3: System Interface3-3HDDIndicates SAS/SATA channel activity and/or DVD-ROM drive activity when fl ashing. NIC2Indicates network activity on GL
3-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual3-4 Hard Drive Carrier LEDsThe SC116AC chassis supports the use of 10 SAS/SATA drives. SAS/SA
4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in ei
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
4-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the sys
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソー
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th
4-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrec
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X9DRW-CF31
4-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einhe
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
4-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must co
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstem
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual Warning!When installing the product, use the provided or designated connection cables, power
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable
NotesPrefacev
5-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the ca
Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. Control Panel Header Pins5-3 Rear I/O PortsSee Figure 5-2 below for the colors and locations of t
5-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual7. With the CPU in the socket, in-spect the four corners of the CPU to make sure that they ar
Chapter 5: Advanced Serverboard Setup5-7Figure 5-3. Installing the HeatsinksFigure 5-4. Securing a HeatsinkNote: be aware that the heatsink for CPU1
5-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory SupportThe X9DRW-CF31/CTF31 supports up to 1024 GB of ECC Load-Reduced (LRDIMM), up to
Chapter 5: Advanced Serverboard Setup5-9DIMM Module Population TableFollow the tables below when installing memory.Processors and their Corresponding
5-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes:Using DDR3 DIMMs with different operating frequencies is not allowed. All channels in a
Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI Add-On CardsThe 1027R-WC1R/1027R-WC1RT can accommodate two full-height, half-length PCI-E 3.0
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 5-6. X9DRW-CF31/CTF31 Layout5-7 Serverboard DetailsNotes• " " indicates t
Chapter 5: Advanced Serverboard Setup5-13Jumper Description Default Setting JBT1 Clear CMOS See Section 5-9JI2C1/JI2C2 SMB to PCI-E Slots Pins 2-3 (No
5-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the
Chapter 5: Advanced Serverboard Setup5-15Overheat (OH)/Fan Fail/PWR Fail/UID LEDConnect an LED cable to pins 7 and 8 of Front Control Panel to use the
5-16SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFan HeadersThere are six fan headers on the serverboard, all of which are 4-pin fans (Fan 1-F
Chapter 5: Advanced Serverboard Setup5-17Ethernet PortsTwo Ethernet ports are located on the I/O backplane. LAN ports 1/2 support gigabit LAN connecti
5-18SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualT-SGPIO HeaderThe SGPIO (Serial General Purpose Input/Output) header is used to com-municate
Chapter 5: Advanced Serverboard Setup5-19DOM Power ConnectorA power connector for SATA DOM (Disk On Module) devices is located at JSD1. Connect an app
5-20SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualStandby Power HeaderThe +5V Standby Power header is lo-cated at JSTBY1. See the table on the
Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con
vii3-2 Control Panel Buttons ... 3-1Power ...
5-22SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualBMC Enable Jumper JPB1 allows you to enable the embedded the Winbond WPCM 450 BMC (Baseboard
Chapter 5: Advanced Serverboard Setup5-235-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,
5-24SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual5-11 SATA and SAS PortsSATA PortPin Defi nitionsPin# Defi nition Pin Defi niti
Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.s
5-26SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or w
Chapter 5: Advanced Serverboard Setup5-275-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged b
5-28SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the fr
Chapter 6: Advanced Chassis Setup6-36-3 System FansIt is very important that the chassis top cover is properly installed and making a good seal in ord
viiiSUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualMemory Support ...
6-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualFigure 6-2. Replacing a System Fan13
Chapter 6: Advanced Chassis Setup6-5Checking the Airfl owCheck the Airfl ow1. Make sure there are no objects obstructing the airfl ow in and out of the
6-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual4. Insert the drive carrier into its bay, keeping the carrier oriented so that the hard drive
Chapter 6: Advanced Chassis Setup6-7Figure 6-4. Removing a Hard Drive1112Caution: Use caution when working around the hard drive backplane. Do not to
6-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual6-5 Power SupplyThe SC116 chassis comes equipped with two redundant 700W-750W power sup-plies.
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X9DRW-CF31/X9DRW-CTF31. It also provides
7-2SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manual7-2 Main SetupWhen you fi rst enter the AMI BIOS setup utility, you will enter the Main setup
Chapter 7: BIOS7-37-3 Advanced Setup Confi gurationsUse the arrow keys to select Advanced Setup and press <Enter> to access the following subme
7-4SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualInterrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk feature.
Chapter 7: BIOS7-5• Type of CPU• CPU Signature• Microcode Patch• CPU Stepping• Maximum CPU Speed• Minimum CPU Speed• Processor Cores• Intel HT (Hyper-
Chapter 1 Introduction1-1 OverviewThe SuperServer 1027R-WC1R/1027R-WC1RT is comprised of two main sub-systems: the SC116AC-R700WB 1U chassis and the X
7-6SUPERSERVER 1027R-WC1R/1027R-WC1RT User's Manualapplications that rely on direct access to the system memory. The options are Optimal and Alte
Chapter 7: BIOS7-7DCU IP PrefetcherSelect Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch IP addresses to improve networ
7-8SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualC1E (Available when Power Technology is set to Custom)Select Enabled to enable Enhanced C1 Pow
Chapter 7: BIOS7-9Long Duration MaintainedThis item displays the period of time in seconds during which long duration power is maintained.Recommended
7-10SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualDCA SupportSelect Enabled to use Intel's DCA (Direct Cache Access) Technology to improve
Chapter 7: BIOS7-11MesegEnSelect Enabled for Message support. The options are Enabled and Disabled.QPI (Quick Path Interconnect) Link Speed ModeUse th
7-12SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualCPU Socket 2 DIMM InformationP2-DIMME1/P2-DIMME2/P2-DIMMF1/P2-DIMMF2/P2-DIMMG1/P2-DIMMG2/P2-D
Chapter 7: BIOS7-13source). Memory is updated as well. Select Enabled to use Demand Scrubbing for ECC memory correction. The options are Enabled and D
7-14SUPERSERVER 1027R-WC1R/1027R-WC1RT User's ManualSelect Enabled to support legacy USB devices. Select Auto to disable legacy sup-port if USB d
Chapter 7: BIOS7-15Port 0~3 Hot PlugSelect Enabled to enable hot-plug support for a particular port, which will allow the user to change a hardware co
Comments to this Manuals