SUPERSERVER 6016T-URF4+SUPERSERVER 6016T-NTRF4+ SUPER®USER’S MANUAL1.0
1-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-URF4+/6016T-NTRF4+ lies the X8
7-28SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Single or dual Intel® 5500/5600 Series processors in LGA1366 soc
B-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualServerboard X8DTU-LN4F+ (Proprietary form factor) Dimensions: 14.85 x 12.68 in
B-3Appendix B: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 C
B-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes(continued from front)The products sold by Supermicro are not intended for and will not
1-3Chapter 1: IntroductionGraphics ControllerThe X8DTU-LN4F+ features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 memory.O
1-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualCooling SystemThe SC819TQ-R700U has an innovative cooling design that features fi ve sets of
1-5Chapter 1: IntroductionFigure 1-1. Intel IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 f
1-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jo
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 6016T-URF4+/6016T-
2-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equi
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the 60
Chapter 2: Server Installation2-5Installing the Outer RailsInstalling the Outer Rails to the RackMeasure the distance from the front rail to the rear
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualInstalling the Server into the RackInstalling the Chassis into a Rack (Figure 2-3)Confi rm th
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack
2-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-5 Checking the Serverboard SetupAfter you install the system in the rack, you will need t
Chapter 2: Server Installation2-9Figure 2-4. Accessing the Inside of the System
2-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive ca
3-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualHDDIndicates IDE channel activity. On the 6016T-URF4+/6016T-NTRF4+ this light indi-cates HDD
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
3-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area aro
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
4-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place whe
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks
5-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and re
Chapter 5: Advanced Serverboard Setup5-3After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south
5-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualThermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mounting holes are
Chapter 5: Advanced Serverboard Setup5-5Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence shown
5-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the
Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)See the Connector Defi nitions section in this chapter for det
SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTU-LN
5-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUT
Chapter 5: Advanced Serverboard Setup5-9Memory Support for 5500 Processor(s)RDIMM Population w/5500 Processors InstalledDIMM Slots per ChannelDIMMs Po
5-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes: Memory speed support depends on the type of CPU used. Due to OS limita-tions, some o
Chapter 5: Advanced Serverboard Setup5-11Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (4 GB Total
5-12SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual6016T-URF4+ PCI Slot/Card Confi gurationsRiser Card Expansion Card SupportedRSC-R1UU-UE16 (l
Chapter 5: Advanced Serverboard Setup5-13Figure 5-4. SUPER X8DTU-LN4F+ Layout5-7 Serverboard DetailsNotes:Jumpers not indicated are for test purposes
5-14SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualX8DTU-LN4F+ Quick ReferenceJumper Description Default SettingJBT1 Clear CMOS See Section 5-
Chapter 5: Advanced Serverboard Setup5-155-8 Connector Defi nitionsPower LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the
5-16SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located on pins 11 and 1
Chapter 5: Advanced Serverboard Setup5-17Reset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware reset
vPrefaceNotes
5-18SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFan HeadersThe X8DTU-LN4F+ has eight fan headers, designated Fan1 through Fan8. FAN1 throug
Chapter 5: Advanced Serverboard Setup5-19ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located beside the U
5-20SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualLAN1/2/3/4 (Ethernet Ports)Four Ethernet ports (designated LAN1, LAN2, LAN3 and LAN4) are l
Chapter 5: Advanced Serverboard Setup5-21NIC3/NIC4 LED HeadersA LAN3 (NIC3) LED and LAN4 (NIC4) LED header is located at JPK1. Con-nect the appropriat
5-22SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualTrusted Platform Module HeaderA Trusted Platform Module (TPM) header (JTPM) is located next
Chapter 5: Advanced Serverboard Setup5-235-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c
5-24SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualLAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 and/or JPL2 to enable or disable
Chapter 5: Advanced Serverboard Setup5-255-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabi
5-26SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-11 SATA Port ConnectionsSATA PortsSee the table on the right for pin defi nitions for the
Chapter 5: Advanced Serverboard Setup5-275-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system
viSUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-28SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports
Chapter 5: Advanced Serverboard Setup5-29Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S
5-30SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the
Chapter 6: Advanced Chassis Setup6-36-3 System FansFive 4-cm heavy duty counter-rotating fans provide the cooling for the 6016T-URF4+/6016T-NTRF4+. Ea
6-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFigure 6-2. System Cooling FansAccessing the Drive BaysSATA Drives: Because of their hotswa
Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr
6-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualInstalling/Removing a Hard DriveTo remove a carrier, push the release button located beside
Chapter 6: Advanced Chassis Setup6-7DVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay
viiTable of ContentsChapter 3 System Interface3-1 Overview ...
6-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual6-4 Power SupplyThe SuperServer 6016T-URF4+/6016T-NTRF4+ has a 700 watt redundant power supp
Chapter 6: Advanced Chassis Setup6-9Figure 6-5. Removing/Replacing the Power Supply
6-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-LN4F+. The AMI ROM BIOS is stored in
7-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is th
Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time
7-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter&
Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and
7-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualClock Spread SpectrumSelect Enable to use the feature of Clock Spectrum, which will allow th
Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Simultaneous Multi-Threading Technology,
viiiSUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-11 SATA Port Connections ...
7-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualXAdvanced Chipset ControlThe items included in the Advanced Settings submenu are listed belo
Chapter 7: BIOS7-9Memory Mode The options are Independent, Channel Mirror, and Lockstep.Independent - All DIMMs are available to the operating system.
7-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualIntel I/OATThe Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead
Chapter 7: BIOS7-11USB FunctionsThis feature allows the user to decide the number of onboard USB ports to be en-abled. The Options are: Disabled, 2 US
7-12SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualICH AHCI Codebase (Available when the option-AHCI is selected.)Use this feature to select t
Chapter 7: BIOS7-13Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be dete
7-14SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSelect UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3
Chapter 7: BIOS7-15SXB1 PCI-E 2.0 x16/x8 Option ROM/SXB3 PCI-E 2.0 x8 Option ROM/SXB2 PCI-E 2.0 x8/x4 Option ROM/SXB2 PCI-E 2.0 x4 Option ROMSelect En
7-16SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSerial Port NumberThis feature allows the user decide which serial port to be used for Cons
Chapter 7: BIOS7-17CPU Overheat AlarmThis option allows the user to select the CPU Overheat Alarm setting which de-termines when the CPU OH alarm will
Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-URF4+/6016T-NTRF4+ is a high-end server comprised of two main subsystems: the SC819TQ-R700U 1U
7-18SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manualseeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU
Chapter 7: BIOS7-19Select "Balanced/BL" for the onboard fans to run at a speed that will balance the needs between system cooling and power
7-20SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNUMA SupportSelect Enabled to use the feature of Non-Uniform Memory Access to improve CPU p
Chapter 7: BIOS7-21TPM Owner StatusThis item displays the status of TPM Ownership.XIPMI Confi gurationIntelligent Platform Management Interface (IPMI)
7-22SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual Event Data.• Clear BMC System Event LogClear BMC System Log nowSelect OK and press the <
Chapter 7: BIOS7-23Gateway Address (When IP Address Source is set to 'Static') The BIOS will automatically enter the Gateway address of this
7-24SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use bot
Chapter 7: BIOS7-25Clear User Password (Available only when User Password has been set)This item allows you to clear a user password after it has been
7-26SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1st Drive - [RAID: XXXXXXXXX]• Retry Boot DevicesSelect Enabled to enable Retry Boot Device
Chapter 7: BIOS7-27Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK
Comments to this Manuals