Supermicro X8DTU-6TF+ User Manual Page 50

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 49
3-24
X8DTU-6F+/X8DTU-6TF+/X8DTU-6(T)F+-LR User's Manual
Power Button
Blue+ (OH/Fan Fail/
PWR FaiL/UID LED
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue Led Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Active LED
NIC1 Active LED
X8DTU-6F+
B
A. NIC 2 Link LED
B. NIC 2 Activity LED
C. OH/Fan Fail/PWR Fail/UID LED (Red LED)
D. UID LED (Blue)
A
NIC2 LED Indicator
The Network LED connections for
GLAN port 2 are located on pins 9 and
10 of JF1. Attach a NIC LED cable to
display LAN Port2 connections and
activities. Refer to the table on the
right for pin de nitions.
GLAN2 LED
Pin De nitions (JF1)
Pin# De nition
9 NIC2 Activity
10 NIC2 Link
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED cable to pins 7 and
8 of JF1 to use the Overheat/Fan Fail/
Power Fail/UID LED connections.
Refer to Page 3-20 for more informa-
tion on UID Switches/LED Indicators.
See the tables on the right for pin
de nitions.
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin De nitions (JF1)
Pin# De nition
7 Blue_LED Cathode (UID)
8 OH/Fan Fail/PWR Fail/UID LED
OH/Fan Fail/PWR Fail LED Status
Pin 7 Pin 8 Red LED Blue LED
Low High On: OH/FF/PWR Fail
(Solid On: OH
Fast Blinking: Fan Fail
Slow Blinking: PWR Fail)
Off
High Low Off
(System: Normal)
On
UID LED
High High Off Off
C
D
Page view 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 110 111