Page 1 - X10SRH-CF/

X10SRH-CF/CLN4FUSER’S MANUAL Revision 1.0

Page 2

x X10SRH-CF/CLN4F User’s ManualAdvanced Power Management Conguration ... 4-8Power Technology ...

Page 3 - Manual Organization

4-26 X10SRH-CF/CLN4F Motherboard User’s ManualOnboard LAN1 Option ROM/Onboard LAN2 Option ROM/Onboard LAN3 Option ROM/Onboard LAN4 Option

Page 4

Chapter 4: AMI BIOS4-27Device SettingsThis item displays the base I/O port address and the Interrupt Request address of a serial port specied by the

Page 5 - Contacting Supermicro

4-28 X10SRH-CF/CLN4F Motherboard User’s Manualclient computer. A lower transmission speed may be required for long and busy lines. The opt

Page 6 - Table of Contents

Chapter 4: AMI BIOS4-29Use this item to select the number of rows and columns used in Console Redi-rection for legacy OS support. The options are 80x

Page 7

4-30 X10SRH-CF/CLN4F Motherboard User’s ManualUse this feature to set the data transmission size for Console Redirection. The options are

Page 8 - Chapter 4 BIOS

Chapter 4: AMI BIOS4-31This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The

Page 9

4-32 X10SRH-CF/CLN4F Motherboard User’s ManualUse this item to set the ow control for Console Redirection to prevent data lo

Page 10

Chapter 4: AMI BIOS4-33ACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) plat-form and provide a com

Page 11

4-34 X10SRH-CF/CLN4F Motherboard User’s Manual4-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Set

Page 12

Chapter 4: AMI BIOS4-35Memory Correctable Error ThresholdUse this item to enter the threshold value for correctable memory errors. The default setting

Page 13

xiTable of ContentsAbove 4G Decoding (Available if the system supports 64-bit PCI decoding) 4-24SR-IOV (Available if the system supports Single-Root V

Page 14

4-36 X10SRH-CF/CLN4F Motherboard User’s Manual4-5 IPMIUse this feature to congure Intelligent Platform Management Interface (I

Page 15 - •One (1) I/O shield

Chapter 4: AMI BIOS4-37When SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem event log is full. Select Er

Page 16

4-38 X10SRH-CF/CLN4F Motherboard User’s Manual4-6 Security SettingsThis menu allows the user to congure the following security

Page 17 - X10SRH-CF

Chapter 4: AMI BIOS4-394-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how

Page 18

4-40 X10SRH-CF/CLN4F Motherboard User’s Manual•Dual Boot Order #7•Dual Boot Order #8•Dual Boot Order #9•Dual Boot Order #10•Dual Boot

Page 19

Chapter 4: AMI BIOS4-41Hard Disk Drive BBS Priorities•Legacy Boot Order #1 - Legacy Boot Order #10Network Drive BBS Priorities•Legacy Boot Order #

Page 20

4-42 X10SRH-CF/CLN4F Motherboard User’s Manual4-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to

Page 21 - Motherboard Features

Chapter 4: AMI BIOS4-43Restore DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are manufacture

Page 22

4-44 X10SRH-CF/CLN4F Motherboard User’s ManualNotes

Page 23 - LGA2011-3

Appendix A: POST Error Beep CodesA-1Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th

Page 24

xii X10SRH-CF/CLN4F User’s ManualHigh Precision Timer ... 4-33NUMA (Avail

Page 25 - 1-2 Chipset Overview

A-2 X10SRH-CF/CLN4F User’s ManualNotes

Page 26 - 1-4 PC Health Monitoring

Appendix B: Software Installation InstructionsB-1Appendix B Software Installation Instructions B-1 Installing Software ProgramsThe Supermicro ftp

Page 27 - 1-6 Power Supply

B-2 X10SRH-CF/CLN4F Motherboard User’s ManualB-2 Installing SuperDoctor5The Supermicro SuperDoctor® 5 is a hardware monitoring program that function

Page 28 - 1-7 Super I/O

Appendix C: UEFI BIOS RecoveryC-1Appendix C UEFI BIOS Recovery Instructions Warning: Do not upgrade the BIOS unless your system has a BIOS-related i

Page 29 - Installation

C-2 X10SRH-CF/CLN4F User’s Manual5. When the screen as shown above displays, using the arrow key, select the item- "Proceed with ash update&quo

Page 30

Appendix C: UEFI BIOS RecoveryC-36. After the process of BIOS Recovery is complete, press any key to reboot the system.7. Using a different system,

Page 31 - Product Disposal

C-4 X10SRH-CF/CLN4F User’s Manual9. After seeing the message that BIOS update is completed, unplug the AC pow-er cable from the power supply to clear

Page 32 - Unpacking

Appendix D: Dual Boot BlockD-1Appendix DDual Boot Block on Grantley PlatformsOverviewOn X10 Grantley platforms, Supermicro introduces the Dual Boot Bl

Page 33 - Location of Mounting Holes

D-2 X10SRH-CF/CLN4F User’s ManualD-1 IPMI GUI BrowserTo perform perform the Dual Boot Block through the IPMI GUI browser, follow the instructions bel

Page 34 - Installing the Motherboard

Appendix D: Dual Boot BlockD-33. Click on the Remote Control tab, then Console Redirection, then the Launch Console button to open the Java iKVM View

Page 35 - OPEN 1st

xiiiBoot Mode Select ... 4-39Fixed Boot Order Priorities ...

Page 36

D-4 X10SRH-CF/CLN4F User’s Manual5. In the Virtual Media loader, click on the Device1 tab, then Logical Drive Type drop-down menu, then select the US

Page 37

Appendix D: Dual Boot BlockD-57. After the system powers on, the secondary boot block starts to initialize the essential hardware components and loca

Page 38

D-6 X10SRH-CF/CLN4F User’s Manual9. A message box will appear to indicate the BIOS recovery ash process is complete. Press ENTER to nish. The syste

Page 39

Appendix D: Dual Boot BlockD-7D-2 IPMI Command SetsTo perform perform the Dual Boot Block through the IPMI Command Sets, follow the instructions belo

Page 40 - Removing the Heatsink

D-8 X10SRH-CF/CLN4F User’s Manual3. Enable BIOS Resilience mode in remote IPMI and conrm. •To enable, type the following command in the command pro

Page 41 - 2-5 Installing DDR4 Memory

Appendix D: Dual Boot BlockD-95. Power on the remote system for BIOS recovery ash.•To power on, type: ipmi power upAfter the system powers on, the

Page 42 - Guidelines

D-10 X10SRH-CF/CLN4F User’s ManualNotes

Page 43 - Chapter 2: Installation

(Disclaimer Continued)The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fa

Page 44 - 2-6 Connectors/IO Ports

xiv X10SRH-CF/CLN4F User’s ManualNotes

Page 45

Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged le

Page 46

1-2 X10SRH-CF/CLN4F User’s Manual X10SRH-CF/CLN4F Motherboard ImageNote: All graphics shown in this manual were based upon the latest PCB Revision a

Page 47

Chapter 1: Introduction1-3X10SRH-CF/CLN4F Motherboard LayoutNotes:•See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front panel c

Page 48 - Front Control Panel

1-4 X10SRH-CF/CLN4F User’s ManualX10SRH-CF/CLN4F JumpersJumper Description DefaultJBR1 BIOS Recovery Pins 1-2 (Normal)JBT1 CMOS Clear (See Chapter 2)J

Page 49

Chapter 1: Introduction1-5X10SRH-CF/CLN4F Headers/ConnectorsConnector DescriptionBT1 Onboard BatteryCOM1/COM2 COM1 (Port)/COM2 (Header)Fan1 - Fan5

Page 50

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 51

1-6 X10SRH-CF/CLN4F User’s ManualX10SRH-CF/CLN4F LED IndicatorsLED Description State/Color StatusLE1 UID LED Blue On Unit IdentiedLE2 Power LED On Po

Page 52

Chapter 1: Introduction1-7Motherboard FeaturesCPU Single Intel® E5-2600/1600 Series Processor in an LGA2011 R3 socket.Memory Supports DDR4 memory up

Page 53 - 2-7 Connecting Cables

1-8 X10SRH-CF/CLN4F User’s ManualPlug and Play (PnP), DMI 2.3, PCI 2.3, ACPI 1.0/2.0/3.0, USB Keyboard and SMBIOS 2.5Power Conguration ACPI/APM Power

Page 54

Chapter 1: Introduction1-9System Block DiagramNote: This is a general block diagram and may not exactly represent the features on your motherboard. Se

Page 55

1-10 X10SRH-CF/CLN4F User’s ManualSystem Block DiagramNote: This is a general block diagram and may not exactly represent the features on your motherb

Page 56 - Standby Power

Chapter 1: Introduction1-111-2 Chipset Overview The X10SRH-CF/CLN4F supports a single Intel® E5-2600/1600 Series Processor in an LGA2011 R3 socket. B

Page 57

1-12 X10SRH-CF/CLN4F User’s Manual1-3 Special FeaturesRecovery from AC Power LossBasic I/O System (BIOS) provides a setting for you to determine how

Page 58

Chapter 1: Introduction1-131-5 ACPI FeaturesACPI stands for Advanced Conguration and Power Interface. The ACPI specica-tion denes a exible a

Page 59 - 2-8 Jumper Settings

1-14 X10SRH-CF/CLN4F User’s Manualto shield the computer from noise. It is recommended that you also install a power surge protector to help avoid pro

Page 60

Chapter 2: Installation2-1Chapter 2 Installation2-1 Standardized Warning StatementsThe following statements are industry-standard warnings, provided

Page 61

iiiPrefacePrefaceThis manual is written for system integrators, IT professionals, and knowledgeable end users. It provides information for the insta

Page 62

2-2 X10SRH-CF/CLN4F User’s ManualAttention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une

Page 63

Chapter 2: Installation2-3Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations

Page 64 - (X8ST3-F)

2-4 X10SRH-CF/CLN4F User’s Manual2-2 Static-Sensitive DevicesElectrostatic-Discharge (ESD) can damage electronic com ponents. To avoid dam-aging you

Page 65 - BMC: Normal

Chapter 2: Installation2-5DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-311

Page 66 - SAS Heartbeat LED Status

2-6 X10SRH-CF/CLN4F User’s ManualInstalling the Motherboard1. Install the I/O shield into the back of the chassis. 2. Locate the mounting holes on t

Page 67 - 2-10 SATA Connections

Chapter 2: Installation2-72-4 Processor and Heatsink InstallationWarning: When handling the processor package, avoid placing direct pressure on the

Page 68

2-8 X10SRH-CF/CLN4F User’s ManualGently push down to pop the load plate open.2. Press the second load lever labeled 'Close 1st' to release

Page 69 - Troubleshooting

Chapter 2: Installation2-94. Using your thumb and the index nger, loosen the CPU lever and open the load plate.5. Use your thumb and index nger to

Page 70 - Memory Errors

2-10 X10SRH-CF/CLN4F User’s ManualOPEN 1stOPEN 1st7. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is

Page 71 - •System conguration

Chapter 2: Installation2-11OPEN 1stMotherboardScrew#1Screw#2Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or th

Page 72

ivConventions Used in the Manual:Special attention should be given to the following symbols for proper system instal-lation: Warning: Critical inform

Page 73 - Battery Installation

2-12 X10SRH-CF/CLN4F User’s ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed. However, if you do need t

Page 74

Chapter 2: Installation2-13DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 75 - Chapter 4

2-14 X10SRH-CF/CLN4F User’s ManualRemoving Memory ModulesReverse the steps above to remove the DIMM modules from the motherboard.Memory SupportThe X10

Page 76 - 4-2 Main Setup

Chapter 2: Installation2-15Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (-Available)(4 GB Total S

Page 77

2-16 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 78 - Boot Feature

Chapter 2: Installation2-17DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 79 - Power Conguration

2-18 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 80 - CPU Conguration

Chapter 2: Installation2-19DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 81

2-20 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 82

Chapter 2: Installation2-21DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 83

vContacting SupermicroContacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408) 503-800

Page 84

2-22 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 85 - IIO Conguration

Chapter 2: Installation2-23DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 86

2-24 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 87

Chapter 2: Installation2-25DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 88 - QPI Status

2-26 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 89 - Memory Conguration

Chapter 2: Installation2-27DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 90 - •P2-DIMMA2 - P2-DIMMD2

2-28 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 91 - •USB Devices

Chapter 2: Installation2-29DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 92

2-30 X10SRH-CF/CLN4F User’s ManualAA. TPM/Port 80TPM Header/Port 80 HeaderA Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM

Page 93 - •Software Preserve Support

Chapter 2: Installation2-31DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 94

viTable of ContentsPrefaceAbout This Motherboard ... iiiM

Page 95

2-32 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 96

Chapter 2: Installation2-33DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 97

2-34 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 98 - PCIe/PCI/PnP Conguration

Chapter 2: Installation2-35DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 99

2-36 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 100 - Super IO Conguration

Chapter 2: Installation2-37DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 101

2-38 X10SRH-CF/CLN4F User’s ManualDESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA

Page 102

Chapter 2: Installation2-39DESIGNED IN USA1.00REV:X10SRH-CFSAS CODE1BIOS LICENSEIPMI CODEMAC CODEBAR CODE321123PCH SLOT2 PCI-E 2.0 X4(IN X8)LGA2011-31

Page 103

2-40 X10SRH-CF/CLN4F User’s ManualNotes

Page 104

3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting 3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If

Page 105

viiTable of ContentsRemoving Memory Modules ... 2-14Memory Support ...

Page 106

3-2 X10SRH-CF/CLN4F User’s ManualNo Video1. If the power is on, but you have no video--in this case, you will need to re-move all the add-on cards an

Page 107 - ACPI Settings

3-3Chapter 3: Troubleshooting3-2 Technical Support ProceduresBefore contacting Technical Support, please make sure that you have followed all the ste

Page 108 - 4-4 Event Logs

3-4 X10SRH-CF/CLN4F User’s Manual3-3 Frequently Asked QuestionsQuestion: What type of memory does my motherboard support?Answer: The X10SRH-CF/CLN4F

Page 109 - View SMBIOS Event Log

3-5Chapter 3: Troubleshooting3-4 Battery Removal and InstallationBattery RemovalTo remove the onboard battery, follow the steps below:1. Power off y

Page 110 - 4-5 IPMI

3-6 X10SRH-CF/CLN4F User’s Manual3-5 Returning Merchandise for ServiceA receipt or copy of your invoice marked with the date of purchase is required

Page 111 - •IPMI Network Link Status

Chapter 4: AMI BIOS4-1Chapter 4 BIOS 4-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRL-CF/CLN4F. The ROM BIOS is st

Page 112 - 4-6 Security Settings

4-2 X10SRH-CF/CLN4F Motherboard User’s ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is

Page 113 - 4-7 Boot Settings

Chapter 4: AMI BIOS4-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. High

Page 114

4-4 X10SRH-CF/CLN4F Motherboard User’s Manual4-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <E

Page 115 - •UEFI Boot Order #1

Chapter 4: AMI BIOS4-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error o

Page 116 - 4-8 Save & Exit

viiiWatch Dog Enable/Disable ... 2-34BMC Enable ...

Page 117

4-6 X10SRH-CF/CLN4F Motherboard User’s ManualCPU CongurationWarning: Setting the wrong values in the following sections may cause the sy

Page 118

Chapter 4: AMI BIOS4-7Select Enable to support Intel's Hyper-threading Technology to enhance CPU per-formance. The options are Enable and Disable

Page 119 - BIOS Error Beep Codes

4-8 X10SRH-CF/CLN4F Motherboard User’s ManualDCU ModeUse this feature to set the data-prefecting mode for the DCU (Data Cache Unit). The o

Page 120 - X10SRH-CF/CLN4F User’s Manual

Chapter 4: AMI BIOS4-9If the option is set to Energy Efcient or Custom, the following items will display:Cong TDP (Conguring Thermal Design Power)S

Page 121 - Appendix B

4-10 X10SRH-CF/CLN4F Motherboard User’s ManualCPU C6 Report (Available when Power Technology is set to Custom)Select Enable to allow the B

Page 122 - B-2 Installing SuperDoctor5

Chapter 4: AMI BIOS4-11Package Clamping Limit1Use this item to set the limit on power performance states for the runtime proces-sor, with P0 being the

Page 123 - Appendix C

4-12 X10SRH-CF/CLN4F Motherboard User’s ManualPORT 1A Link SpeedThis item congures the link speed of a PCI-E port specied by the use

Page 124

Chapter 4: AMI BIOS4-13IOAT (Intel® IO Acceleration) CongurationEnable IOATSelect Enable to enable Intel I/OAT (I/O Acceleration Technology) support

Page 125

4-14 X10SRH-CF/CLN4F Motherboard User’s ManualQPI (Quick Path Interconnect) CongurationQPI StatusThe following information will display

Page 126

Chapter 4: AMI BIOS4-15Memory CongurationEnforce PORSelect Enable to enforce POR restrictions on DDR4 frequency and voltage programming. The options

Page 127 - Appendix D

ixTable of Contentsused in the system was built. ... 4-3Memory Information ...

Page 128 - D-1 IPMI GUI Browser

4-16 X10SRH-CF/CLN4F Motherboard User’s ManualChannel InterleavingUse this item to set DIMM channel interleaving mood. The options are Aut

Page 129 - Appendix D: Dual Boot Block

Chapter 4: AMI BIOS4-17Patrol ScrubPatrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module

Page 130

4-18 X10SRH-CF/CLN4F Motherboard User’s ManualXHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI (

Page 131

Chapter 4: AMI BIOS4-19SATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA devices that are suppo

Page 132

4-20 X10SRH-CF/CLN4F Motherboard User’s ManualPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by

Page 133 - D-2 IPMI Command Sets

Chapter 4: AMI BIOS4-21Serial ATA Port 0~ Port 5This item displays the information detected on the installed SATA drives on the particular SATA port.•

Page 134

4-22 X10SRH-CF/CLN4F Motherboard User’s Manual*If the item above "Congure sSATA as" is set to AHCI, the following

Page 135 - User Approach

Chapter 4: AMI BIOS4-23Port 0 ~ Port 3 sSATA Device Type (Available when a SATA port is detected)Use this item to specify if the sSATA port specied b

Page 136

4-24 X10SRH-CF/CLN4F Motherboard User’s ManualServer ME (Management Engine) CongurationThis feature displays the following system ME con

Page 137

Chapter 4: AMI BIOS4-25Maximum PayloadSelect Auto for the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance sys