Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5017C-
MTF/5017C-MTRF up and running. Following the steps in the order given should en-
able you to have the system operational within a minimal amount of time. This quick
setup assumes that your 5017C-MTF/5017C-MTRF system has come to you with
the processor and memory preinstalled. If your system is not already fully integrated
with a motherboard, processor, system memory etc., please turn to the chapter or
section noted in each step for details on installing speci c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 5017C-MTF/5017C-MTRF was shipped
in and note if it was damaged in any way. If the server itself shows damage, you
should le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 5017C-
MTF/5017C-MTRF. It should be situated in a clean, dust-free area that is well
ventilated. Avoid areas where heat, electrical noise and electromagnetic elds are
generated. You will also need it placed near a grounded power outlet. Read the
Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 5017C-MTF/5017C-MTRF was shipped in should include
two sets of rail assemblies, six rail mounting brackets and the mounting screws
you will need to install the system into the rack. Follow the steps in the order given
to complete the installation process in a minimal amount of time. Please read this
section in its entirety before you begin the installation procedure outlined in the
sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suf cient air ow and ease in servicing.This product is for