SUPERSERVER 5017C-MTF
SUPERSERVER 5017C-MTRF
SUPER
®
USER’S MANUAL
1.0
Page view 0
1 2 3 4 5 6 ... 93 94

Summary of Contents

Page 1 - SUPER

SUPERSERVER 5017C-MTF SUPERSERVER 5017C-MTRF SUPER®USER’S MANUAL1.0

Page 2 - Manual Revision 1.0

1-2SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5017C-MTF/5017C-MTRF lies the X9SCL-F, a

Page 3 - Manual Organization

1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MTQ chassis.System PowerWhen

Page 4

1-4SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualFigure 1-1. Intel C200 Chipset: System Block DiagramNote: This is a general block diagram. Plea

Page 5

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Page 6 - Table of Contents

1-6SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes

Page 7 - Chapter 4 System Safety

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5017C-

Page 8

2-2SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipmen

Page 9 - Introduction

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Page 10 - 1-2 Motherboard Features

2-4SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperS

Page 11 - 1-3 Server Chassis Features

Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 5017C-MTF/5017C-MTRF in the rack (see Rack

Page 12 - System Block Diagram

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 13 - 1-4 Contacting Supermicro

2-6SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the S

Page 14

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a Te

Page 15 - Server Installation

2-8SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual2-5 Checking the Motherboard SetupAfter you install the 5017C-MTF/5017C-MTRF in the rack, you w

Page 16 - Warnings and Precautions!

Chapter 2: Server Installation2-9Figure 2-4.Accessing the Inside of the SuperServer 5017C-MTF/5017C-MTRF2-6 Checking the Drive Bay SetupNext, you sho

Page 17 - Rack Mounting Considerations

2-10SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualAlso note that all power and data cables have been routed in such a way that 2. they do not blo

Page 18

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive ca

Page 19 - Installing the Rack Rails

3-2SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTQ chassis has fi ve L

Page 20

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Page 21

3-4SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes

Page 22

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Page 23 - Release buttons

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 24

SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around

Page 25 - System Interface

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Page 26 - 3-3 Control Panel LEDs

SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when th

Page 27 - 3-4 Hard Drive Carrier LEDs

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install processors and heatsinks

Page 28

5-2SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual5-2 Processor and Heatsink InstallationNotes: Always connect the power cord last and always rem

Page 29 - System Safety

Chapter 5: Advanced Motherboard Setup5-3Use your thumb and your index fi nger to hold the CPU at the top center edge 3. and the bottom center edge of t

Page 30

5-4SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualCPU properly installedLoad lever locked into place.Warning: The CPU will only seat inside the so

Page 31 - 4-3 ESD Precautions

Chapter 5: Advanced Motherboard Setup5-5Figure 5-3. Installing the HeatsinkOnce the CPU is loose, remove the it from the CPU socket.3. Clean the surfa

Page 32 - BATTERY HOLDER

5-6SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the cabl

Page 33 - Advanced Motherboard Setup

Chapter 5: Advanced Motherboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)All JF1 wires have been bundled into single keyed ribbon cabl

Page 34 - Load Plate

SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a gener

Page 35

5-8SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONE

Page 36 - Removing the Heatsink

Chapter 5: Advanced Motherboard Setup5-9Note: Due to memory allocation to system devices, the amount of memory that remains available for operational

Page 37

5-10SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual5-6 Adding PCI CardsPCI Expansion SlotsOne riser card is used to support a PCI expansion (add-

Page 38 - 5-3 Connecting Cables

Chapter 5: Advanced Motherboard Setup5-11Figure 5-4. SUPER X9SCL-F Layout5-7 Motherboard DetailsJ31JTPMJ29JL1JI2C2JI2C1T-SGPIO1JWF1JPW2JWOLJSPKJPI2CJ

Page 39 - 5-4 I/O Ports

5-12SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualLED IndicatorsNumber LED Description14 LE7 IPMI Heartbeat LED (IPMI Active)28 LE2 Onboard Stand

Page 40 - 5-5 Installing Memory

Chapter 5: Advanced Motherboard Setup5-135-8 Connector Defi nitions ATX Power Connector A 24-pin main power connector is located at JPW1. This power co

Page 41

5-14SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNIC1/NIC2 (LAN1/LAN2)The NIC (Network Interface Controller) LED connection for LAN port 1 is lo

Page 42 - 5-6 Adding PCI Cards

Chapter 5: Advanced Motherboard Setup5-15Universal Serial Bus (USB)Two Universal Serial Bus ports (USB 0/1) are located on the I/O backpanel and an ad

Page 43 - 5-7 Motherboard Details

5-16SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualFan HeaderPin Defi nitions Pin# Defi nition 1 Ground (Black)2 2.5A/+12V (Red)3 Tachometer

Page 44 - Headers/Connectors

Chapter 5: Advanced Motherboard Setup5-17Power Supply I2C ConnectorThe Power Supply (I2C) connector is located at JPI2C on the motherboard. This conne

Page 46

5-18SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualDOM PWR ConnectorA Disk On Module (DOM) Power Con-nector is located at JWF1. This connec-tor is

Page 47 - NC = No connection

Chapter 5: Advanced Motherboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to

Page 48

5-20SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualLAN Port Enable/DisableUse JPL1/JPL2 to enable or disable LAN Ports 1 and 2 on the motherboard.

Page 49

Chapter 5: Advanced Motherboard Setup5-215-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Page 50

5-22SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual5-11 SATA Drive ConnectionsSATA PortsSix Serial ATA (SATA) ports (I-SATA 0~5) are located on t

Page 51 - 5-9 Jumper Settings

Chapter 5: Advanced Motherboard Setup5-235-12 Installing DriversAfter all the hardware and operating system have been installed, you need to install c

Page 52

5-24SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remo

Page 53 - 5-10 Onboard Indicators

Chapter 5: Advanced Motherboard Setup5-25Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S

Page 54 - 5-11 SATA Drive Connections

5-26SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes

Page 55 - 5-12 Installing Drivers

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 56 - Supero Doctor III

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 57

6-2SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the ch

Page 58

Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance fans provide the cooling for the SuperServer 5017C-MTF/5017C-MTRF. The c

Page 59 - Advanced Chassis Setup

6-4SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualUse caution when working around the SATA backplane. Do not touch the backplane with any metal ob

Page 60 - 6-2 Control Panel

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Drive in a CarrierSATA BackplaneThe SATA drives plug into a backplane that provides power,

Page 61 - 6-3 System Fans

6-6SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the

Page 62 - SATA Drive Installation

Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 5017C-MTF has a single 350 watt power supply. This power sup-ply has the capabilit

Page 63 - SATA Backplane

6-8SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualThe SuperServer 5017C-MTRF has a 400 watt redundant power supply consisting of two power modules

Page 64 - DVD-ROM Drive Installation

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X9SCL-F. The AMI ROM BIOS is stored in a Fl

Page 65 - 6-5 Power Supply

7-2SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is th

Page 66

Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time

Page 67 - Chapter 7

viiTable of ContentsChapter 3 System Interface3-1 Overview ...

Page 68 - 7-2 Main Setup

7-4SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter>

Page 69

Chapter 7: BIOS7-519 at boot and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disab

Page 70 - BOOT Feature

7-6SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualAdjacent Cache Line Prefetch (Available when supported by the CPU)The CPU fetches the cache line

Page 71 - Processor & Clock Options

Chapter 7: BIOS7-7P-STATE CoordinationThis feature selects the type of coordination for the P-State of the processor. P-State is a processor operatio

Page 72

7-8SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNorth Bridge Confi gurationThis item displays the current North Bridge Revision.VT-dSelect Enabl

Page 73 - Chipset Confi guration

Chapter 7: BIOS7-9Wake on LAN from S5Select Enabled to enable the capabiltiy to 'wake-up' the system from the S5 power state (Soft Off State

Page 74

7-10SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualAggressive Link Power ManagementThis feature Enables or Disables Agressive Link Power Managemen

Page 75 - IDE/SATA Confi guration

Chapter 7: BIOS7-11PCI Latency TimerThis feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to

Page 76 - PCIe/PCI/PnP Confi guration

7-12SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualSerial Port 2 ModeUse this feature to confi gure Serial Port 2 mode. The options are Normal, IrD

Page 77

Chapter 7: BIOS7-13Parity: None, Even, Odd, Mark, or SpaceStop Bits: 1 or 2Hardware Health Confi gurationFan Speed Control ModeThis feature allows the

Page 78 - Remote Access Confi guration

viiiSupero Doctor III ... 5-24Chapter 6 Advanced Chassis Setup

Page 79 - Hardware Health Confi guration

7-14SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualHigh – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Temperature Tol

Page 80 - ACPI Confi guration

Chapter 7: BIOS7-157-4 Event LogsSmbios Event LogChange this item to enable or disable all features of the Smbios Event Logging during boot. The opti

Page 81 - 7-4 Event Logs

7-16SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual7-5 IPMI Confi gurationIntelligent Platform Management Interface (IPMI) is a set of common inter

Page 82 - 7-5 IPMI Confi guration

Chapter 7: BIOS7-17SEL Components - Change this item to enable or disable all features of System Event Logging. The options are Enabled and Disabled.

Page 83 - BMC Network Confi guration

7-18SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual7-6 Boot SettingsUse this feature to confi gure Boot Settings:Boot Options PriorityThis feature

Page 84 - 7-6 Boot Settings

Chapter 7: BIOS7-197-7 Security SettingsIf the Administrator password is defi ned ONLY - this controls access to the • BIOS setup ONLY.If the User&apos

Page 85 - 7-7 Security Settings

7-20SUPERSERVER 5017C-MTF/5017C-MTRF User's Manual7-8 Exit OptionsSelect the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS S

Page 86 - 7-8 Exit Options

Chapter 7: BIOS7-21Save As User DefaultsTo set this feature, select Save as User Defaults from the Exit menu and press <En-ter>. This enables th

Page 87

7-22SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes

Page 88

Appendix A: POST Error Beep CodesA-1Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Page 89 - BIOS Error Beep Codes

Chapter 1 Introduction1-1 OverviewThe SuperServer 5017C-MTF/5017C-MTRF is a high-end server comprised of two main subsystems: the SC813MTQ-350B/SC813M

Page 90

A-2SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes

Page 91 - System Specifi cations

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Single Intel® Xeon® E3-1200 Series processor or a CoreTM i3-2100

Page 92

B-2SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualChassis SC813MTQ Form Factor: 1U rackmount Dimensions: (WxHxD) 17.2 x 1.7 x 19.85 i

Page 93 - Regulatory Compliance

B-3Appendix B: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR

Page 94

B-4SUPERSERVER 5017C-MTF/5017C-MTRF User's ManualNotes