Supermicro X7SBA User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 89
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
1-10
X7SBA Users Manual
1-3 PC Health Monitoring
This section describes the PC health monitoring features of the X7SBA. The
motherboard has an onboard System Hardware Monitor chip that supports PC
health monitoring.
Onboard Voltage Monitors
The onboard voltage monitor will scan the voltages for the CPU Cores, Chipset
Voltage, Memory Voltage, +1.8V, +3.3V, +3.3V Standby, +5V, +5V Standby, +12V,
and −12V continuously (via SuperO Doctor III). Once a voltage becomes unstable,
it will give a warning or send an error message to the screen. The user can adjust
the voltage thresholds to dene the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Speed Control
The PC health monitor can check the RPM status of the cooling fans. The on-
board fans are controlled by Thermal Management via Hardware Monitoring in
the BIOS.
CPU Overheat/Fan Fail LED and Control
This feature is available when the user enables the CPU overheat warning func-
tion in the BIOS. This allows the user to dene an overheat temperature. When
the temperature reaches the predened threshold, the CPU thermal trip feature
will be activated and it will send a signal to the Speaker LED and, at the same
time, the CPU speed will be decreased. It will also activate the alarm if a fan
failure occurs.
Recovery from AC Power Loss
BIOS provides a setting for you to determine how the system will respond when
AC power is lost and then restored to the system. You can choose for the system
to remain powered off (in which case you must hit the power switch to turn it
back on) or for it to automatically return to a power on state. See the Power Lost
Control setting in the BIOS chapter to change this setting. The default setting is
Last State.
1-4 PowerCongurationSettings
This section describes features of your motherboard that deal with power and
power settings.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking
to indicate that the CPU is in suspend mode. When the user presses any key, the
CPU will wake-up and the LED will automatically stop blinking and remain on.