Page 1 - SUPER

®SuperWorkstation7037A-I SUPERUSER’S MANUAL1.0a

Page 2 - Release Date: July 16, 2012

SuperWorkstation 7037A-I User's Manual1-21-2 Serverboard FeaturesAt the heart of the SuperWorkstation 7037A-I lies the X9DAi, a dual processor se

Page 3 - Manual Organization

B-2SuperWorkstation 7037A-I User's ManualWeight Gross (Bare Bone): 39 lbs (17.7 kg.)System Cooling One 12-cm low-noise exhaust fan

Page 4

B-3Appendix B: System Specifi cationsNotes

Page 5

B-4SuperWorkstation 7037A-I User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life

Page 6 - Table of Contents

1-3Chapter 1: Introduction1-3 Chassis FeaturesThe SC732D4F-903B is mid-tower chassis. The following is a general outline of the main features of the c

Page 7

SuperWorkstation 7037A-I User's Manual1-4Figure 1-1. Intel C600 Chipset: System Block DiagramNote: This is a general block diagram. Please see C

Page 8 - Chapter 7 BIOS

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Page 9 - • Optional:

SuperWorkstation 7037A-I User's Manual1-6Notes

Page 10 - 1-2 Serverboard Features

Chapter 2: Installation2-1Chapter 2 Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperWorkstation 7037A-I up and

Page 11 - 1-3 Chassis Features

2-2SuperWorkstation 7037A-I User's Manual• To maintain proper cooling, always keep all chassis panels closed and all SATA carriers installed when

Page 12 - System Block Diagram

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 7037A-I has several LEDs and a power button. There are al

Page 13 - 1-4 Contacting Supermicro

3-2SuperWorkstation 7037A-I User's ManualHDDIndicates IDE channel activity on the SATA drive, and/or DVD-ROM drive activity when fl ashing.NICIndi

Page 14

Chapter 3: System Interface3-3Overheat/Fan FailWhen this LED fl ashes, it indicates a chassis fan failure. When on continuously it indicates an overhea

Page 15 - Installation

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 16

3-4SuperWorkstation 7037A-I User's ManualNotes

Page 17 - • Two USB 2.0 ports

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Page 18 - 3-4 Control Panel LEDs

SuperWorkstation 7037A-I User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety: • Keep the area around the S

Page 19 - 3-4 Drive Carrier LEDs

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Page 20

SuperWorkstation 7037A-I User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the system

Page 21 - System Safety

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X9DAi serverboard in

Page 22

5-2SuperWorkstation 7037A-I User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When

Page 23 - 4-3 ESD Precautions

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Page 24 - A O

5-4SuperWorkstation 7037A-I User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2

Page 25 - Advanced Serverboard Setup

Chapter 5: Advanced Serverboard Setup5-55-5 Processor and Heatsink InstallationWhen handling the processor package, avoid placing direct pressure on

Page 26 - 5-2 Serverboard Installation

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 27 - • Control Panel cable (JF1)

5-6SuperWorkstation 7037A-I User's ManualGently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retra

Page 28 - 20 19

Chapter 5: Advanced Serverboard Setup5-7Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inse

Page 29 - Pull lever away

5-8SuperWorkstation 7037A-I User's Manual Screw#1Screw#2Installing a CPU HeatsinkNote: heatsinks are optional parts.1. Do not apply an

Page 30 - WARNING!

Chapter 5: Advanced Serverboard Setup5-9Removing the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed. However, if you do

Page 31 - OPEN 1st

5-10SuperWorkstation 7037A-I User's Manual5-6 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTIO

Page 32 - Installing a CPU Heatsink

Chapter 5: Advanced Serverboard Setup5-11Memory SupportThe X9DAi supports up to 512 GB of registered/unbuffered load reducing ECC DDR3 1333/1066/833 m

Page 33 - Removing the Heatsink

5-12SuperWorkstation 7037A-I User's ManualUDIMM Memory SupportRanks Per DIMM & Data WidthMemory Capacity Per DIMM (Note 1)Speed (MT/s) and Vo

Page 34

Chapter 5: Advanced Serverboard Setup5-13LRDIMM Memory SupportRanks Per DIMM & Data Width (Note 1)Memory Capacity Per DIMM (Note 2)Speed (MT/s) an

Page 35 - Memory Support

5-14SuperWorkstation 7037A-I User's ManualDIMM Population TableDIMM Slots per ChannelDIMMs Populated per ChannelDIMM Type (Reg.= Registered)Speed

Page 36 - RDIMM Memory Support

Chapter 5: Advanced Serverboard Setup5-155-7 Adding PCI Add-On CardsThe 7037A-I can accommodate standard size add-on cards populated in all slots on

Page 37

SuperWorkstation 7037A-I User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X9DAi serverboard, i

Page 38

5-16SuperWorkstation 7037A-I User's ManualFigure 5-4. X9DAi Layout5-8 Serverboard DetailsNotes:• " " indicates the location of "P

Page 39 - 5-7 Adding PCI Add-On Cards

Chapter 5: Advanced Serverboard Setup5-17X9DAi Quick Reference Jumper Description Default Setting JBT1 Clear CMOS See Section 5-10JP4 SMBus En/Disable

Page 40 - 5-8 Serverboard Details

5-18SuperWorkstation 7037A-I User's ManualConnector DescriptionJSPDIF_Out SPDIF (Sony/Philips Digital Interface) Out HeaderJTPM1 TPM (Trusted Pla

Page 41 - X9DAi Quick Reference

Chapter 5: Advanced Serverboard Setup5-19Reset ConnectorThe reset header is located on pins 3 and 4 of JF1. Attach the reset switch on the computer ch

Page 42

5-20SuperWorkstation 7037A-I User's ManualOverheat/Fan Fail LED (OH)Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis

Page 43 - 5-9 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-21Fan HeadersThe X9DAi has eight fan headers, all of which are 4-pin fans. However, pins 1-3 of the fan headers

Page 44

5-22SuperWorkstation 7037A-I User's ManualTPM Header/Port 80A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM support a

Page 45

Chapter 5: Advanced Serverboard Setup5-23SGPIO HeaderTwo SGPIO (Serial General Purpose Input/Output) headers are designated T-SGPIO1 and SGPIO2. These

Page 46

5-24SuperWorkstation 7037A-I User's ManualSPDIF_In/SPDIF_Out HeadersThe SPDIF In (JSPDIF_In) and SP-DIF Out (JSPDIF_Out) headers are located nex

Page 47

Chapter 5: Advanced Serverboard Setup5-255-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to

Page 48

vPrefaceNotes

Page 49 - 5-10 Jumper Settings

5-26SuperWorkstation 7037A-I User's ManualGLAN Enable/DisableChange the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2 Eth

Page 50

Chapter 5: Advanced Serverboard Setup5-27ME Mode SelectJumper Settings Jumper Setting Defi nition Pins 1-2 Manufacture ModePins 2-3 Normal (Def

Page 51

5-28SuperWorkstation 7037A-I User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On ea

Page 52 - 5-12 SATA Ports

Chapter 5: Advanced Serverboard Setup5-295-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system

Page 53 - 5-13 Installing Software

5-30SuperWorkstation 7037A-I User's ManualSupero Doctor III Interface Display Screen (Health Information)SuperDoctor IIIThe SuperDoctor® III pro

Page 54 - SuperDoctor III

Chapter 5: Advanced Serverboard Setup5-31Supero Doctor III Interface Display Screen (Remote Control)Note: The SuperDoctor III program and User's

Page 55

5-32SuperWorkstation 7037A-I User's ManualNotes

Page 56

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple ma

Page 57 - Advanced Chassis Setup

6-2SuperWorkstation 7037A-I User's Manual6-2 Accessing the Inside of the SystemThe SC732 features two removable side covers, allowing easy acces

Page 58

Chapter 6: Advanced Chassis Setup6-3Figure 6-2. Rotating the Hard Drive Cage6-3 Rotating the Hard Drive CageIn order to access and install component

Page 59 - HDD Cage (B)

viSuperWorkstation 7037A-I User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 60

6-4SuperWorkstation 7037A-I User's Manual6-4 Removing and Installing 3.5" Hard DrivesThe SC732 chassis must be powered-down before hard dri

Page 61

Chapter 6: Advanced Chassis Setup6-56. If a hard drive is already present, remove it by carefully pulling the sides of the hard drive carrier outward

Page 62 - Optional

6-6SuperWorkstation 7037A-I User's ManualFigure 6-5. Installing a Hard Drive Carrier into the Hard Drive Cage11119Optional Screw

Page 63

Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Removing a 2.5" Hard Drive1415Thumb Screw6-5 Removing and Installing 2.5" Hard DrivesThe S

Page 64

6-8SuperWorkstation 7037A-I User's ManualFigure 6-7. Installing 2.5" Hard Drives5. If a hard drive is already present, remove it by carefu

Page 65 - Cover Plate

Chapter 6: Advanced Chassis Setup6-96-6 Installing a 3.5" DeviceThe SC732D chassis has one 3.5" device slot, which supports an optional dev

Page 66 - 6-7 Installing System Fans

6-10SuperWorkstation 7037A-I User's Manual6-7 Installing System FansInstalling the Rear Exhaust Fan1. Disconnect all power to the chassis.2. I

Page 67

Chapter 6: Advanced Chassis Setup6-11Installing the Front Cooling Fan (Optional)1. Disconnect all power to the chassis.2. Insert the four rubber pin

Page 68

6-12SuperWorkstation 7037A-I User's Manual6-8 Installing the Front BezelFront Bezel Installation1. Insert the tabs on the front bezel into the

Page 69 - 6-9 Power Supply

Chapter 6: Advanced Chassis Setup6-136-9 Power SupplyThe SC732 chassis includes a 900 Watt power supply. In the unlikely event that it becomes necessa

Page 70

viiTable of ContentsChapter 5 Advanced Serverboard Setup5-1 Handling the Serverboard ...

Page 71 - Chapter 7

6-14SuperWorkstation 7037A-I User's ManualNotes

Page 72 - 7-2 Main Setup

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup utility for the X9DA6/X9DAi. It also provides the instruc

Page 73 - XBoot Features

7-2SuperWorkstation 7037A-I User's ManualNote: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Re-covery User Guide posted @http://www.

Page 74 - Power Confi guration

Chapter 7: BIOS7-3System TimeThis item displays the system time in HH:MM:SS format (e.g. 15:32:52).Supermicro X9DA6 SMC VersionThis item displays the

Page 75 - CPU Confi guration

7-4SuperWorkstation 7037A-I User's ManualAddOn ROM Display ModeUse this item to set the display mode for the Option ROM. Select Keep Current to u

Page 76

Chapter 7: BIOS7-5EuPSelect Enabled to support the Low-power Compliance Mode for Energy-using Products (EuP). The options are Enable and Disable.CPU C

Page 77

7-6SuperWorkstation 7037A-I User's Manual64-bit This item indicates if the CPU installed in Socket 0 supports 64-bit technology.Clock Spread Spec

Page 78 - XIntegrated IO Confi guration

Chapter 7: BIOS7-7L1 Data Prefetch (Available when supported by the CPU)Select Enabled to enable Level 1 data prefetch support to enhance system perfo

Page 79 - XQPI Confi guration

7-8SuperWorkstation 7037A-I User's ManualRecommended Short Duration PowerThis item displays the short duration power settings recommended by the

Page 80 - XDIMM Information

Chapter 7: BIOS7-9Port 1A Link SpeedSelect GEN1 to enable PCI-Exp Generation 1 support for Port 1A. Select GEN2 to enable PCI-Exp Generation 2 suppor

Page 81

viiiSuperWorkstation 7037A-I User's ManualChapter 7 BIOS 7-1 Introduction ...

Page 82 - Auto Confi guration

7-10SuperWorkstation 7037A-I User's ManualQPI Link Frequency SelectUse this feature to select the desired QPI frequency. The options are Auto, 6.

Page 83 - XSATA Confi guration

Chapter 7: BIOS7-11Rank InterleavingThis feature allows the user to select a rank memory interleaving method. The options are Auto, 1 Way, 2 Way, 4, W

Page 84 - XPCIe/PCI/PnP Confi guration

7-12SuperWorkstation 7037A-I User's ManualXSouth Bridge Confi gurationThis feature allows the user to confi gure the settings for the Intel PCH chi

Page 85

Chapter 7: BIOS7-13Azalia Internal HDMI DecodeSelect Enabled to enable support for Azalia High Defi nition Muliti-Media Interface Decode. The options a

Page 86 - • COM 1/COM 2

7-14SuperWorkstation 7037A-I User's ManualRAID ModeThe following items are displayed when RAID Mode is selected:PCH RAID CodeBaseSelect Intel or

Page 87

Chapter 7: BIOS7-15PERR# GenerationSelect Enabled to allow a PCI device to generate a PERR number for a PCI Bus Signal Error Event. The options are En

Page 88 - XACPI Setting

7-16SuperWorkstation 7037A-I User's ManualXSerial Port Console Redirection• COM 1/COM 2These two submenus allow the user to confi gure the followi

Page 89 - XME Subsystem Confi guration

Chapter 7: BIOS7-17Stop BitsA stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 S

Page 90 - • ME Version

7-18SuperWorkstation 7037A-I User's ManualCPU 1 Temperature/CPU 2 TemperatureThe CPU Temperature feature will display the CPU temperature status

Page 91 - • Error Code

Chapter 7: BIOS7-19High Precision Event TimerSelect Enabled to activate HPET, which produces periodic interrupts at a much higher frequency than a Rea

Page 92 - • Sensor

Chapter 1 Introduction1-1 OverviewThe 7037A-I is a high-end workstation comprised of two main subsystems: the SC732D4F-903B tower/4U chassis and the X

Page 93 - 7-6 Security

7-20SuperWorkstation 7037A-I User's Manual• ME BIOS Interface Version• ME VersioniSCSI: This item displays the following iSCSI information:iSCSI

Page 94 - 7-7 Save & Exit

Chapter 7: BIOS7-21Memory Correctable Error ThresholdThis feature allows the user to enter the threshold value for correctable memory errors. The defa

Page 95 - • UEFI: Built-in EFI Shell

7-22SuperWorkstation 7037A-I User's Manual• SeverityView System Event LogThis item allows the user to view the event in the system event log. Sel

Page 96

Chapter 7: BIOS7-23Boot Option PrioritiesBoot Option #1This item allows the user to select the fi rst boot drive. Select a LAN device to boot the syste

Page 97 - BIOS Error Beep Codes

7-24SuperWorkstation 7037A-I User's ManualAdministrator PasswordUse this feature to set the Administrator Password which is required to enter the

Page 98

Chapter 7: BIOS7-25ing, click Yes to quit BIOS without saving the changes, or click No to quit the BIOS and save changes.Save OptionsSave ChangesSelec

Page 99 - System Specifi cations

7-26SuperWorkstation 7037A-I User's ManualNotes

Page 100

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system

Page 101

A-2SuperWorkstation 7037A-I User's ManualNotes

Page 102

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Two Intel E5-2600 processors in LGA 2011 sockets Note: Ple