Supermicro X9SRL-F User Manual

Browse online or download User Manual for Server/workstation motherboards Supermicro X9SRL-F. Supermicro X9SRL-F

  • Download
  • Add to my manuals
  • Print
  • Page
    / 109
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - USER’S MANUAL

USER’S MANUAL Revision 1.0aX9SRLX9SRL-F

Page 2

x X9SRL Motherboard Series User’s ManualTurbo Mode ... 4-

Page 3 - Manual Organization

A-2 X9SRL Motherboard Series User's ManualNotes

Page 4

Appendix B: Software Installation InstructionsB-1Driver/Tool Installation Display ScreenNote 1. Click the icons showing a hand writing on the paper to

Page 5 - Contacting Supermicro

B-2 X9SRL Motherboard Series User's ManualSuperDoctor III Interface Display Screen-I (Health Information)B-2 Conguring SuperDoctor® IIIThe Sup

Page 6 - Table of Contents

Appendix B: Software Installation InstructionsB-3Note: The SuperDoctor III software and manual may be downloaded from our Website at: http://www.super

Page 7

B-4 X9SRL Motherboard Series User's ManualNotes

Page 8

UEFI BIOS RecoveryC-1Appendix C UEFI BIOS Recovery InstructionsWarning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashin

Page 9

X9SRL Motherboard Series User’s ManualC-2Note: At this point, you may decide if you want to start with BIOS Recovery. If you decide to proceed with

Page 10

UEFI BIOS RecoveryC-3Note: Do not interrupt the process of BIOS ashing until it is completed. Aptio Setup Utility - Copyright (C) 2011 American Meg

Page 11

X9SRL Motherboard Series User’s ManualC-48. When a DOS prompt appears, type AMI.BAT BIOSname.### at the prompt. Note: Do not interrupt this proces

Page 12

(Disclaimer Continued)The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fa

Page 13 - •One (1) User's Manual

xiACPIConguration ... 4-18High Precision Event Timers ...

Page 14

xii X9SRL Motherboard Series User’s ManualRestore Optimized Defaults ... 4-27Save As

Page 15 - BAR CODE

Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged le

Page 16

1-2 X9SRL Motherboard Series User’s ManualNote: All graphics shown in this manual were based upon the latest PCB Revision available at the time of pub

Page 17

Chapter 1: Introduction1-3Motherboard Layout1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 18 - Motherboard Features

1-4 X9SRL Motherboard Series User’s ManualMotherboard Quick ReferenceCOM21JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D

Page 19

Chapter 1: Introduction1-5Motherboard Headers/ConnectorsConnector DescriptionCOM2 / COM1 Serial port (COM1) and header (COM2)JOH1 Overheat LED/Fan Fai

Page 20 - Intel C602

1-6 X9SRL Motherboard Series User’s ManualMotherboard FeaturesCPU Single Intel® E5-1600 and E5-2600 processor in an LGA 2011 pin Socket-R (4~8 Core)Me

Page 21 - 1-2 Chipset Overview

Chapter 1: Introduction1-7BIOS 32 Mb SPI AMI BIOS® SM Flash BIOSPlay and Plug APM 1.2, DMI 2.3, PCI 2.2, ACPI 1.0/2.0, USB Keyboard and SMBIOS 2.3Powe

Page 22 - 1-4 PC Health Monitoring

Manual Revision 1.0aRelease Date: July 3, 2012Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any

Page 23 - 1-6 Power Supply

1-8 X9SRL Motherboard Series User’s ManualSystem Block DiagramNote: This is a general block diagram and may not exactly represent the features on your

Page 24 - 1-7 Super I/O

Chapter 1: Introduction1-91-2 Chipset Overview The Intel® C602 series is a single chip solution that is designed for dedicated servers and workstatio

Page 25

1-10 X9SRL Motherboard Series User’s Manual1-3 Special FeaturesRecovery from AC Power LossBasic I/O System (BIOS) provides a setting for you to dete

Page 26

Chapter 1: Introduction1-11usedtonotifytheuserofcertainsystemevents.Forexample,youcanalsocongureSupero Doctor to provide you with warn

Page 27 - Installation

1-12 X9SRL Motherboard Series User’s ManualIt is strongly recommended that you use a high quality power supply that meets ATX powersupplySpecicatio

Page 28

Chapter 1: Introduction1-131-9 Introduction to the IPMI Controller (-F Models Only)This motherboard incorporates the Renesas IPMI Controller, which i

Page 29 - The LGA2011 Socket

1-14 X9SRL Motherboard Series User’s ManualNotes

Page 30 - WARNING!

Chapter 2: Installation2-1Chapter 2 Installation2-1 Static-Sensitive DevicesElectrostatic-Discharge (ESD) can damage electronic com ponents. To avo

Page 31

2-2 X9SRL Motherboard Series User’s Manual2-2 Processor and Heatsink InstallationWarning: When handling the processor package, avoid placing

Page 32 - OPEN 1st

Chapter 2: Installation2-3 Press down on Load Lever 'Open 1st'Opening the LGA2011 Socket 1. There are two load levers on the LGA2011 socket

Page 33

iiiPrefacePrefaceThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installati

Page 34 - Removing the Heatsink

2-4 X9SRL Motherboard Series User’s Manual2. Press the second load lever labeled 'Close 1st' to release the load plate which covers the CP

Page 35

Chapter 2: Installation2-5WARNING!Installing the LGA2011 Processor 1. With the LGA 2011 socket open, remove the 'WARNING' plastic cap using

Page 36

2-6 X9SRL Motherboard Series User’s Manual3. Once it is aligned, carefully lower the CPU straight down into the socket. (Do not drop the CPU on the

Page 37 - Memory Population Guidelines

Chapter 2: Installation2-7OPEN 1stMotherboardScrew#1Screw#2Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the

Page 38 - 2-4 Motherboard Installation

2-8 X9SRL Motherboard Series User’s ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed. However, if you

Page 39 - Installing the Motherboard

Chapter 2: Installation2-91JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-SA

Page 40 - 2-5 Connectors/IO Ports

2-10 X9SRL Motherboard Series User’s ManualMemory SupportThe X9SRL Motherboard Series supports up to 256GB of 1600/1066/1333/1600 MHz ECC/Non-ECC

Page 41

Chapter 2: Installation2-11Memory Population GuidelinesWhen installing memory modules, the DIMM slots should be populated in the follow-ing or

Page 42

2-12 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 43 - 3. COM2 Serial Port (header)

Chapter 2: Installation2-13Installing the Motherboard1. Install the I/O shield into the chassis. 2. Locate the mounting holes on the motherboard. 3.

Page 44 - Pin 19Pin 20

iv X9SRL Motherboard Series User’s ManualConventions Used in the Manual:Special attention should be given to the following symbols for proper installa

Page 45

2-14 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 46

Chapter 2: Installation2-15ATX PS/2 Keyboard/Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are located on the Back Panel of the motherb

Page 47

2-16 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 48 - 5 through 8 +12V

Chapter 2: Installation2-17COM/Serial PortsA Serial Port (COM1) is located on the I/O backpanel, and another Se-rial Port (COM2) is located next

Page 49

2-18 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 50 - KB/MOUSE

Chapter 2: Installation2-19Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2HDD LEDPower LED#3~4#1~2VccVccVccUID LEDGroundGround1920XXVccNIC2 LEDNMIGr

Page 51

2-20 X9SRL Motherboard Series User’s ManualNIC1/NIC2 (LAN1/LAN2)The NIC (Network Interface Control-ler) LED connection for LAN port 1 is located on p

Page 52

Chapter 2: Installation2-21Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2HDD LEDPower LED#3~4#1~2VccVccVccUID LEDGroundGround1920XXVccNIC2 LEDNMIGr

Page 53

2-22 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 54 - 2-3 Disabled

Chapter 2: Installation2-231JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 55 - Open Disabled

vContacting SupermicroContacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408) 503-8

Page 56

2-24 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 57 - Pins 2-3 Disabled

Chapter 2: Installation2-251JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 58

2-26 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 59 - 2-8 Onboard Indicators

Chapter 2: Installation2-271JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 60

2-28 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 61 - 2-9 SATA and SAS Connections

Chapter 2: Installation2-291JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 62

2-30 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 63 - Troubleshooting

Chapter 2: Installation2-311JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 64 - Memory Errors

2-32 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 65 - •System conguration

Chapter 2: Installation2-331JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 66

vi X9SRL Motherboard Series User’s ManualTable of ContentsPrefaceAbout This Motherboard ...

Page 67

2-34 X9SRL Motherboard Series User’s Manual1JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2

Page 68 - Battery Removal

Chapter 2: Installation2-351JD17JIPMB1CA4581JPW2I-SATA5I-SATA4I-SATA3I-SATA22UID_SW1DIMM_C1DIMM_C2DIMM_D1DIMM_A1DIMM_B1DIMM_A2DIMM_B2DIMM_D2I-SATA1I-S

Page 69

2-36 X9SRL Motherboard Series User’s ManualNotes

Page 70

3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting 3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If

Page 71 - Chapter 4

3-2 X9SRL Motherboard Series User's ManualNo Video1. If the power is on, but you have no video--in this case, you will need to re-move all the a

Page 72 - 4-2 Main Setup

3-3Chapter 3: Troubleshooting3-2 Technical Support ProceduresBefore contacting Technical Support, please make sure that you have followed all the ste

Page 73

3-4 X9SRL Motherboard Series User's Manual3-3 Frequently Asked QuestionsQuestion: What type of memory does my motherboard support?Answer: Pleas

Page 74 - BOOT Feature

3-5Chapter 3: TroubleshootingQuestion: Why do I get an error message “IASTOR.SYS read error” and "press F6 to install Intel RAID driver" whe

Page 75 - CPU Conguration

3-6 X9SRL Motherboard Series User's ManualProper Battery DisposalWarning! Please handle used batteries carefully. Do not damage the bat-tery in a

Page 76

3-7Chapter 3: Troubleshooting3-5 Returning Merchandise for ServiceA receipt or copy of your invoice marked with the date of purchase is required befo

Page 77

viiTable of ContentsRemoving the Heatsink ... 2-72-3 Installing DDR3

Page 78 - North Bridge Conguration

3-8 X9SRL Motherboard Series User's ManualNotes

Page 79 - DIMM Conguration

Chapter 4: AMI BIOS4-1Chapter 4 BIOS 4-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X9SRL Motherboard Series. The AMI ROM

Page 80

4-2X9SRL Motherboard Series User’s ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test

Page 81 - South Bridge Conguration

Chapter 4: AMI BIOS4-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system t

Page 82 - SATA Conguration

4-4X9SRL Motherboard Series User’s Manual4-3 Advanced Setup CongurationsUse the arrow keys to select Boot Setup and hit <Enter> to access the

Page 83 - PCIe/PCI/PnP Conguration

Chapter 4: AMI BIOS4-5Interrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled

Page 84

4-6X9SRL Motherboard Series User’s ManualHyper ThreadingSet to Enabled to use the processor's Hyper Threading Technology feature. The options are

Page 85 - Super IO Conguration

Chapter 4: AMI BIOS4-7Intel® Virtualization Technology (Available when supported by the CPU)Select Enabled to use the feature of Virtualization Techno

Page 86 - Console Redirection Settings

4-8X9SRL Motherboard Series User’s ManualPackage C State LimitIf set to Auto, the AMI BIOS will automatically set the limit on the C-State package reg

Page 87

Chapter 4: AMI BIOS4-9DCA SupportThis feature accelerates the performance of I/O devices using Direct Cache Access. The options are Enabled and Disabl

Page 88 - ACPI Conguration

viii X9SRL Motherboard Series User’s ManualSystem Management Bus (JIPMB) ...2-262-7 Jumper Settings .

Page 89 - ME Subsystem

4-10X9SRL Motherboard Series User’s ManualMemory Mode When Independent is selected, all DIMMs are available to the operating system. When Mirroring is

Page 90 - 4-4 Event Logs

Chapter 4: AMI BIOS4-11Data Scrambling This feature enables Data Scrambling. The options are Enabled and Disabled.Device Tagging This feature enables

Page 91

4-12X9SRL Motherboard Series User’s ManualSATA CongurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of the SATA

Page 92 - 4-5 IPMI Settings

Chapter 4: AMI BIOS4-13RAID ModeThe following items are displayed when RAID Mode is selected:Port 0~5 Hot PlugSet this item to Enabled to enable hot-p

Page 93 - BMC Network Conguration

4-14X9SRL Motherboard Series User’s ManualSERR# GenerationSet this item to Enabled to allow PCI devices to generate SERR# error codes. The options ar

Page 94 - 4-6 Boot Settings

Chapter 4: AMI BIOS4-15Super IO Conguration Serial Port 1 / Serial Port 2Select Enabled to enable the onboard serial port. The options are Enabled a

Page 95 - 4-7 Security Settings

4-16X9SRL Motherboard Series User’s ManualConsole Redirection SettingsThis feature allows the user to specify how the host computer will exchange dat

Page 96 - 4-8 Save & Exit

Chapter 4: AMI BIOS4-17VT-UTF8 Combo Key SupportSelect Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Ena

Page 97

4-18X9SRL Motherboard Series User’s ManualTerminal TypeThis feature allows the user to select the target terminal emulation type for Con-sole Redirect

Page 98

Chapter 4: AMI BIOS4-19Trusted Computing Conguration (Available when a TPM Device is detected by the BIOS)TPM SupportSelect Enable to activate suppo

Page 99 - BIOS Error Beep Codes

ixTable of ContentsChapter 4 BIOS 4-1 Introduction ...

Page 100

4-20X9SRL Motherboard Series User’s Manual4-4 Event LogsUse this feature to congure Event Log settings.Change SmBIOS Event Log SettingsSmbios Event

Page 101 - Appendix B

Chapter 4: AMI BIOS4-21Erase Event LogThis option erases all logged events. The options are No, Yes, Next reset and Yes, Every reset.When Log is Full

Page 102 - B-2 Conguring SuperDoctor

4-22X9SRL Motherboard Series User’s Manual4-5 IPMI SettingsIntelligent Platform Management Interface (IPMI) is a set of common interfaces that IT adm

Page 103

Chapter 4: AMI BIOS4-23BMC Network CongurationSet this feature to congure the IPMI LAN adapter with a network address. Update IPMI LAN Conguration

Page 104

4-24X9SRL Motherboard Series User’s Manual4-6 Boot SettingsUse this feature to congure Boot Settings:Boot Options PrioritiesThis feature allows the

Page 105 - Appendix C

Chapter 4: AMI BIOS4-254-7 Security SettingsThis menu allows the user to congure the following security settings for the system.• If t

Page 106

4-26X9SRL Motherboard Series User’s Manual4-8 Save & ExitSelect the Save & Exit tab from the BIOS Setup Utility screen to perform save and ex

Page 107

Chapter 4: AMI BIOS4-27Discard ChangesSelect this option and press <Enter> to discard all the changes and return to the AMI BIOS Utility Program

Page 108

4-28X9SRL Motherboard Series User’s ManualNotes

Page 109

Appendix A: POST Error Beep CodesA-1Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time th

Comments to this Manuals

No comments