Supermicro SuperServer 1016T-M3FB User Manual

Browse online or download User Manual for Server barebones Supermicro SuperServer 1016T-M3FB. Supermicro SuperServer 1016T-M3FB

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - SUPER

® SUPERUSER’S MANUALRevision 1.0SUPERSERVER 1016T-M3FB

Page 2 - Release Date: April 27, 2009

NotesSUPERSERVER 1016T-M3FB User's Manualx

Page 3 - Manual Organization

A-2SUPERSERVER 1016T-M3FB User's ManualNotes

Page 4

Appendix B: Installing the Windows OSB-1Appendix B Installing the Windows OSAfter all hardware components have been installed, you must fi rst confi gu

Page 5

B-2SUPERSERVER 1016T-M3FB User's ManualB-2 Installing Windows on Non-RAID SystemsInsert Microsoft's Windows Setup CD in the CD drive and th

Page 6 - Table of Contents

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single Intel® Core™ i7, Core™ i7 Extreme processors and Intel Xeo

Page 7 - Chapter 4 System Safety

C-2SUPERSERVER 1016T-M3FB User's ManualChassis Model: SC113MTS-560C (1U Rackmount) Dimensions: (WxHxD) 17.2 x 1.7 x 20 in. (437 x 43 x

Page 8

C-3Appendix C: System Specifi cationsNotes

Page 9

C-4SUPERSERVER 1016T-M3FB User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life su

Page 10

Chapter 1 Introduction1-1 OverviewThe Supermicro SuperServer 1016T-M3FB is a high-end single processor, 1U rackmount server. The 1016T-M3FB is compris

Page 11 - Introduction

1-2SUPERSERVER 1016T-M3FB User's Manual1-2 Motherboard FeaturesThe X8STi-3F is a single processor motherboard based upon Intel's X58 chipset

Page 12 - 1-2 Motherboard Features

Chapter 1: Introduction1-3Onboard Controllers/PortsAn onboard IDE controller supports one fl oppy drive. Onboard I/O backpanel ports include one COM po

Page 13 - Onboard Controllers/Ports

1-4SUPERSERVER 1016T-M3FB User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC113MTS-560C c

Page 14 - 1-3 Server Chassis Features

Chapter 1: Introduction1-51-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Page 15 - 1-4 Contacting Supermicro

1-6SUPERSERVER 1016T-M3FB User's ManualNotes

Page 16

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 1016T-

Page 17 - Server Installation

2-2SUPERSERVER 1016T-M3FB Manual!!Warnings and Precautions!This product is not suitable for use with visual display work place devices • acccording to

Page 18 - Warnings and Precautions!

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Page 19 - Rack Mounting Considerations

Manual Revision 1.0 Release Date: April 27, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurate

Page 20 - SUPERSERVER 1016T-M3FB Manual

2-4SUPERSERVER 1016T-M3FB Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 1016T-M3FB into

Page 21 - Inner Rails

Chapter 2: Server Installation2-5Figure 2-2. Installing Chassis RailsInner RailsThe SC113 chassis includes a set of inner rails in two sections: inne

Page 22 - Outer Rails

2-6SUPERSERVER 1016T-M3FB ManualOuter RailsInstalling the Outer Rails to the Rack (Figures 2-3 and 2-4)Attach the short bracket to the outside of the

Page 23

Chapter 2: Server Installation2-7Figure 2-4. Installing the Outer Rails to the Rack233

Page 24

2-8SUPERSERVER 1016T-M3FB ManualFigure 2-5. Installing the Server into a RackInstalling the Chassis into a Rack (Figure 2-5)Confi rm that chassis incl

Page 25

Chapter 2: Server Installation2-9Installing the Server into a Telco RackTo install the SuperServer 1016T-M3FB into a Telco type rack, use two L-shaped

Page 26

2-10SUPERSERVER 1016T-M3FB Manual2-5 Checking the Serverboard SetupAfter you install the server in the rack, you will need to open the unit to make s

Page 27

Chapter 2: Server Installation2-11Your server system may have come with system memory already installed. 2. Make sure all DIMMs are fully seated in th

Page 28

2-12SUPERSERVER 1016T-M3FB ManualNotes

Page 29 - System Interface

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel to keep you constantly informed of the

Page 30 - 3-3 Control Panel LEDs

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Page 31

3-2SUPERSERVER 1016T-M3FB Manual3-3 Control Panel LEDsThe control panel located on the front of the SC113MTS-560C chassis has fi ve LEDs. These LEDs p

Page 32 - 3-4 Hard Drive Carrier LEDs

Chapter 3: System Interface3-3NIC2Indicates network activity on LAN2 when fl ashing.NIC1Indicates network activity on LAN1 when fl ashing.HDDIndicates I

Page 33 - System Safety

3-4SUPERSERVER 1016T-M3FB Manual3-4 Hard Drive Carrier LEDsEach hard drive carrier has two LEDs.Green:• When illuminated, the green LED on the fro

Page 34

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Page 35 - 4-3 ESD Precautions

SUPERSERVER 1016T-M3FB User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 1016T-

Page 36 - BATTERY HOLDER BATTERY HOLDER

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Page 37 - Advanced Serverboard Setup

SUPERSERVER 1016T-M3FB User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 1016T-M3

Page 38 - 5-2 Serverboard Installation

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8STi-3F serverboard

Page 39 - 5-3 Connecting Cables

5-2SUPERSERVER 1016T-M3FB User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When un

Page 40 - 5-4 I/O Ports

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Page 41 - Plastic Cap

SUPERSERVER 1016T-M3FB User's ManualivChapter 5: Advanced Motherboard SetupChapter 5 provides detailed information on the X8STi-3F motherboard,

Page 42 - Load Plate

5-4SUPERSERVER 1016T-M3FB User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 be

Page 43

Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge

Page 44 - Removing the Heatsink

5-6SUPERSERVER 1016T-M3FB User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and so

Page 45

Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU HeatsinkScrew#1Screw#1Screw#2Screw#2Install Screw#1Notes: The motherboard comes with

Page 46 - Memory Support

5-8SUPERSERVER 1016T-M3FB User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be re-moved. However, if yo

Page 47 - 5-7 PCI Expansion Cards

Chapter 5: Advanced Serverboard Setup5-95-6 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTIONExerci

Page 48 - LSI 1068E

5-10SUPERSERVER 1016T-M3FB User's ManualPossible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (4 GB To

Page 49 - X8STi-3F Quick Reference

Chapter 5: Advanced Serverboard Setup5-115-7 PCI Expansion CardsA riser card is used to support one standard size (full height full length) PCI expan

Page 50 - 5-9 Connector Defi nitions

5-12SUPERSERVER 1016T-M3FB User's ManualFigure 5-4. X8STi-3F Layout(not drawn to scale)5-8 Serverboard DetailsNotesJumpers not indicated are for

Page 51

Chapter 5: Advanced Serverboard Setup5-13X8STi-3F Quick ReferenceJumper Description Default SettingJBMC1 BMC Enable/Disable Pins 1-2 (Enabled)JBT1 CMO

Page 52

vPrefaceNotes

Page 53

5-14SUPERSERVER 1016T-M3FB User's ManualReset ButtonThe reset button (from the computer chassis) connects to pins 3 and 4 of JF1. See the table o

Page 54

Chapter 5: Advanced Serverboard Setup5-15Overheat/Fan Fail/UID LEDConnect an LED to pins 7 and 8 of JF1 to provide UID signals and advanced warning of

Page 55

5-16SUPERSERVER 1016T-M3FB User's ManualFan HeadersThere are six fan headers on the serverboard, all of which are 4-pin fans (pins 1-3 are backwa

Page 56 - 5-10 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is desig-nated JWOL on the serverboard. See the table on the right for pin

Page 57

5-18SUPERSERVER 1016T-M3FB User's ManualUniversal Serial Bus (USB)There are two Universal Serial Bus ports located on the I/O panel. An additiona

Page 58

Chapter 5: Advanced Serverboard Setup5-19Alarm ResetIf three power supply modules are installed, the system can notify you when any of the three fails

Page 59 - LED Color Defi nition

5-20SUPERSERVER 1016T-M3FB User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used

Page 60

Chapter 5: Advanced Serverboard Setup5-21LAN1/2 Enable/Disable Change the setting of jumper JPL1 and JPL2 to enable or disable the LAN1 and LAN2 Ether

Page 61

5-22SUPERSERVER 1016T-M3FB User's ManualSMBus to PCI SlotsJumper Settings (JI2C1/JI2C2)Jumper Setting Defi nition JI2C1: Closed JI2C2:Clos

Page 62 - 5-13 Installing Software

Chapter 5: Advanced Serverboard Setup5-235-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each por

Page 63 - Supero Doctor III

viSUPERSERVER 1016T-M3FB User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 64

5-24SUPERSERVER 1016T-M3FB User's ManualSAS Heartbeat LEDThe SAS Heartbeat LED is desig-nated as LES2. When LES2 blinks, it indicates the SAS por

Page 65 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-255-12 Floppy and SATA and SAS PortsFloppy Drive ConnectorThe fl oppy connector is located near the USB2 port a

Page 66 - 6-3 System Cooling

5-26SUPERSERVER 1016T-M3FB User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating sys

Page 67 - System Fan Failure

Chapter 5: Advanced Serverboard Setup5-27Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management

Page 68 - Hard Drive Installation

5-28SUPERSERVER 1016T-M3FB User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utili

Page 69

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-tena

Page 70 - DVD Drive Installation

6-2SUPERSERVER 1016T-M3FB ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the chassis) mus

Page 71 - 6-5 Power Supply

Chapter 6: Advanced Chassis Setup6-3Adding a System FanTurn off the power to the system and unplug the power cord.1. Remove the chassis cover then rem

Page 72

6-4SUPERSERVER 1016T-M3FB Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysHard Drives: Because of their hotswap capability, you do no

Page 73 - Chapter 7

Chapter 6: Advanced Chassis Setup6-5Align the drive in the carrier so that the screw holes of both line up. Note that 2. there are holes in the carrie

Page 74 - 7-2 Main Setup

viiTable of ContentsChapter 3 System Interface3-1 Overview ...

Page 75

6-6SUPERSERVER 1016T-M3FB ManualFigure 6-4. Removing a Hard Drive12DVD Drive InstallationThe SC113 chassis includes a pre-installed DVD-ROM.Installin

Page 76 - XBOOT Feature

Chapter 6: Advanced Chassis Setup6-7Insert the new drive unit in the slot until the tab locks in place.5. Reconnect the data and power cables.6. Repla

Page 77 - Processor & Clock Options

6-8SUPERSERVER 1016T-M3FB ManualFigure 6-6. Removing/Replacing the Power SupplyRemoving/Replacing the Power Supply (Figure 6-6)First unplug the AC po

Page 78

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8STi-3F. The AMI ROM BIOS is stored in a F

Page 79

7-2SUPERSERVER 1016T-M3FB User's ManualWarning! Do not upgrade the BIOS UNLESS your system has a BIOS-related issue. Flashing the wrong BIOS can

Page 80 - XAdvanced Chipset Control

Chapter 7: BIOS7-3Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appear

Page 81

7-4SUPERSERVER 1016T-M3FB User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to access

Page 82

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The opti

Page 83

7-6SUPERSERVER 1016T-M3FB User's ManualClock Spread SpectrumSelect Enable to use the feature of Clock Spectrum, which will allow the BIOS to moni

Page 84 - IDE / Floppy Confi guration

Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable: Disable GV3 and Enab

Page 85

viiiSUPERSERVER 1016T-M3FB User's ManualMain ATX Power Supply Connector ... 5-14Processor P

Page 86

7-8SUPERSERVER 1016T-M3FB User's ManualC-STATE TechIf enabled, C-State is set by the system automatically to either C2, C3 or C4 state. The optio

Page 87 - XPCI/PnP Confi guration

Chapter 7: BIOS7-9QPI L0s and L1Select Enabled to lower the QPI power state. L0s and L1 are automatically selected by the motherboard. The options are

Page 88 - XRemote Access Confi guration

7-10SUPERSERVER 1016T-M3FB User's ManualInlet TemperatureThis is the temperature detected at the chassis inlet. Each step is in 0.5oC increment.

Page 89 - Hardware Health Confi guration

Chapter 7: BIOS7-11Intel VT-dSelect Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device a

Page 90

7-12SUPERSERVER 1016T-M3FB User's ManualXIDE / Floppy Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence

Page 91 - XACPI Confi guration

Chapter 7: BIOS7-13activate the following submenu screen for detailed options of these items. Set the correct confi gurations accordingly. The items in

Page 92 - XTrusted Computing

7-14SUPERSERVER 1016T-M3FB User's ManualDMA ModeSelect Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE disk drive suppor

Page 93

Chapter 7: BIOS7-15XPCI/PnP Confi guration This feature allows the user to set the PCI/PnP confi gurations for the following items:Clear NVRAMThis featu

Page 94 - XEvent Log Confi guration

7-16SUPERSERVER 1016T-M3FB User's ManualXSuper IO Device Confi guration Serial Port1 Address/ Serial Port2 AddressThis option specifi es the base I

Page 95 - 7-4 Security Settings

Chapter 7: BIOS7-17Redirection After BIOS POSTSelect Disabled to turn off Console Redirection after Power-On Self-Test (POST). Select Always to keep C

Page 96 - 7-5 Boot Confi guration

ixLAN1/2 LEDs ... 5-23Dedicated IPMI LAN LEDs ...

Page 97 - 7-6 Exit Options

7-18SUPERSERVER 1016T-M3FB User's ManualCPU Temperature/System TemperatureThis feature displays current temperature readings for the CPU and the

Page 98

Chapter 7: BIOS7-19Fan Speed Control Modes This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temp

Page 99 - POST Error Beep Codes

7-20SUPERSERVER 1016T-M3FB User's ManualXTrusted ComputingTCG/TPM SupportSelect Yes on this item and enable the TPM jumper on the motherboard to

Page 100

Chapter 7: BIOS7-21Clear BMC System Event LogThis feature is used to clear the System Event Log. Caution: Any cleared information is unrecoverable. Ma

Page 101 - Installing the Windows OS

7-22SUPERSERVER 1016T-M3FB User's ManualStartup Delay - This feature enables or disables startup delay. The options are Enabled and Disabled.PEF

Page 102

Chapter 7: BIOS7-237-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass-words, the Supervisor password mu

Page 103 - System Specifi cations

7-24SUPERSERVER 1016T-M3FB User's ManualUse this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify

Page 104

Chapter 7: BIOS7-257-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save Changes and Exi

Page 105

7-26SUPERSERVER 1016T-M3FB User's Manualfi guration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Ente

Page 106

Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the AMI BIOS. P

Comments to this Manuals

No comments