Page 1 - SUPER

SUPERUSER’S MANUALRevision 1.0®2U Twin2TMSuperServer 5026Ti-BTRF

Page 2

1-2SUPERSERVER 5026Ti-BTRF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5026Ti-BTRF are four X8SiT-F single processor mot

Page 3 - Manual Organization

B-2SUPERSERVER 5026Ti-BTRF User's ManualWhen the Boot Sector Recovery Process is complete, the system will reboot 5. automatically and you will s

Page 4

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsNote: unless noted specs apply to a complete system (both serverboards).Processors

Page 5

C-2SUPERSERVER 5026Ti-BTRF User's ManualSystem Cooling Four 8-cm PWM (Pulse Width Modulated) fansSystem Input Requirements AC Input V

Page 6 - Table of Contents

C-3Appendix C: System Specifi cationsNotes

Page 7 - Chapter 4 System Safety

C-4SUPERSERVER 5026Ti-BTRF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life s

Page 8

Chapter 1: Introduction1-3Figure 1-1. Intel 3420 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for details

Page 9 - Introduction

1-4SUPERSERVER 5026Ti-BTRF User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC827H-R920B 2

Page 10 - 1-2 Motherboard Features

Chapter 1: Introduction1-51-4 2U Twin2: System NotesAs a 2U Twin2 confi guration, the 5026Ti-BTRF is a unique server system. With four system boards in

Page 11 - RoHS 6/6

1-6SUPERSERVER 5026Ti-BTRF User's Manual1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131

Page 12 - 1-3 Server Chassis Features

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get the 5026Ti-BTRF up and

Page 13 - : System Notes

2-2SUPERSERVER 5026Ti-BTRF User's ManualChoosing a Setup LocationLeave enough clearance in front of the rack to enable you to open the front • do

Page 14 - 1-5 Contacting Supermicro

Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f

Page 15 - Server Installation

2-4SUPERSERVER 5026Ti-BTRF User's Manual!Warning: Except for short periods of time, do NOT operate the server without the cover in place. The cha

Page 16 - Warnings and Precautions!

Chapter 2: Server Installation2-52-4 Rack Mounting InstructionsThis section provides information on installing the SC827 chassis into a rack unit wit

Page 17 - Rack Mounting Considerations

Manual Revision 1.0Release Date: May 3, 2010Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any pa

Page 18 - Removing the Protective Film

2-6SUPERSERVER 5026Ti-BTRF User's ManualFigure 2-3. Installing the Inner Rail ExtensionsInstalling the Inner Rail ExtensionsThe SC827 chassis in

Page 19

Chapter 2: Server Installation2-7Outer Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis e

Page 20

2-8SUPERSERVER 5026Ti-BTRF User's ManualFigure 2-5: Installing Into the RackInstalling the Chassis into a RackExtend the outer rails as illustrat

Page 21 - Outer Rack Rails

Chapter 2: Server Installation2-92-5 Checking the Serverboard SetupAfter you install the system in the rack, you will need to access the inside of th

Page 22

2-10SUPERSERVER 5026Ti-BTRF User's Manual2-6 Preparing to Power OnNext, you should check to make sure the SATA drives and the backplane have bee

Page 23

Chapter 2: Server Installation2-11Figure 2-6. Removing a Node from the System121111

Page 24 - 2-6 Preparing to Power On

2-12SUPERSERVER 5026Ti-BTRF User's ManualNotes

Page 25

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are LEDs on the control panels and on the SATA drive carriers to keep you co

Page 26

3-2SUPERSERVER 5026Ti-BTRF User's Manual3-3 Control Panel LEDsIn addition to the LEDs built into the power and UID buttons, each of the four con

Page 27 - System Interface

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Page 28 - 3-4 SATA Drive Carrier LEDs

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Page 29 - System Safety

SUPERSERVER 5026Ti-BTRF User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the serve

Page 30

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Page 31 - 4-3 ESD Precautions

SUPERSERVER 5026Ti-BTRF User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 5026Ti-

Page 32 - BATTERY HOLDER

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the X8SiT-F motherboard

Page 33 - Advanced Motherboard Setup

5-2SUPERSERVER 5026Ti-BTRF User's ManualUnpackingThe motherboard is shipped in antistatic packaging to avoid electrical static dis-charge. When u

Page 34 - 5-2 Motherboard Installation

Chapter 5: Advanced Motherboard Setup5-35-3 Connecting CablesNow that the motherboard is installed, the next step is to connect the cables to the boar

Page 35 - 5-3 Connecting Cables

5-4SUPERSERVER 5026Ti-BTRF User's Manual5-4 Rear I/O PortsThe rear I/O ports are color coded in conformance with the PC 99 specifi cation. See Fi

Page 36 - 5-4 Rear I/O Ports

Chapter 5: Advanced Motherboard Setup5-5Installing the LGA1156 Processor Press the load lever to release the load plate, which covers the CPU socket,

Page 37

5-6SUPERSERVER 5026Ti-BTRF User's ManualGently lift the load lever to open the load plate. Remove the plate cap.2. Use your thumb and your index

Page 38

Chapter 5: Advanced Motherboard Setup5-7Use your thumb to gently push the load lever down to the lever lock.5. Save the plastic PnP cap. The motherboa

Page 39

SUPERSERVER 5026Ti-BTRF User's ManualivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC827H-R920B 2U rackm

Page 40 - Removing the Heatsink

5-8SUPERSERVER 5026Ti-BTRF User's ManualFigure 5-3. Installing the HeatsinkRemoving the HeatsinkWarning: We do not recommend removing the CPU or

Page 41 - 5-6 Installing Memory

Chapter 5: Advanced Motherboard Setup5-9Figure 5-4. Removing the HeatsinkScrew #1MotherboardLoosen screws in the sequence shownScrew #2Screw #3Screw #

Page 42 - Memory Support

5-10SUPERSERVER 5026Ti-BTRF User's ManualPlatform DIMM Type Intel® Xeon® Series ProcessorsX8SiT-F Non-ECC UDIMM Only Not SupportedECC UDIMM Only

Page 43 - Memory Population Guidelines

Chapter 5: Advanced Motherboard Setup5-11Memory Population GuidelinesPlease follow the tables below when populating the X8SIT-F.DDR3 ECC UDIMM Memory

Page 44 - Press Down

5-12SUPERSERVER 5026Ti-BTRF User's ManualFigure 5-3. DIMM InstallationInsert the DIMM module vertically and press down until the module snaps int

Page 45

Chapter 5: Advanced Motherboard Setup5-13Note: Due to memory allocation to system devices, the amount of memory that remains available for operational

Page 46 - 5-8 Motherboard Details

5-14SUPERSERVER 5026Ti-BTRF User's Manual5-7 Adding PCI Expansion CardsThe 5026Ti-BTRF includes four preinstalled riser cards designed specifi ca

Page 47 - BAR CODE

Chapter 5: Advanced Motherboard Setup5-15Figure 5-4. X8SiT-F LayoutY2JTPMMH8MH7MH5MH3MH2MH1MH9JPI2CSPKR1JSPKFAN1FAN2FAN3FA N4T-SGPIO2T-SGPIO1JF1JWR4JW

Page 48

5-16SUPERSERVER 5026Ti-BTRF User's ManualConnectors/HeadersNumber Connector Description1 SW1 Unit ID Switch3 J5 SMB Header for IPMI 2.04 Slot 1 P

Page 49 - 5-9 Connector Defi nitions

Chapter 5: Advanced Motherboard Setup5-17Power ButtonThe Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins w

Page 50

vPrefaceNotes

Page 51

5-18SUPERSERVER 5026Ti-BTRF User's ManualReset ButtonThe reset button (from the computer chassis) connects to pins 3 and 4 of JF1. See the table

Page 52

Chapter 5: Advanced Motherboard Setup5-19Fan HeadersThe X8SiT-F has four fan headers. Fan1 is the CPU fan and Fan2 is for the system cooling fan. Thes

Page 53

5-20SUPERSERVER 5026Ti-BTRF User's ManualUnit ID SwitchThere are three Unit Identifi cation (UID) devices on the motherboard. A rear UID switch an

Page 54

Chapter 5: Advanced Motherboard Setup5-21T-SGPIO 0/1 HeadersTwo T-SGPIO (Serial-Link General Purpose Input/Output) headers are located near the SATA c

Page 55 - 5-10 Jumper Settings

5-22SUPERSERVER 5026Ti-BTRF User's ManualUniversal Serial Bus (USB)Two Universal Serial Bus ports (USB0/1) are located on the I/O back-panel. An

Page 56

Chapter 5: Advanced Motherboard Setup5-235-10 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to

Page 57

5-24SUPERSERVER 5026Ti-BTRF User's ManualSMB Bus to PCI SlotsUse jumpers JI2C1 and JI2C2 to en-able PCI Slot SMB (System Manage-ment Bus) support

Page 58 - 5-11 Onboard Indicators

Chapter 5: Advanced Motherboard Setup5-25BMC Enable/DisableThe JPB jumper is used to enable or disable the onboard Baseboard Man-agement Controller (B

Page 59 - 5-12 SATA Ports

5-26SUPERSERVER 5026Ti-BTRF User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On eac

Page 60 - 5-13 Installing Software

Chapter 5: Advanced Motherboard Setup5-275-12 SATA PortsSATA PortPin Defi nitionsPin# Defi nition Pin # Defi nition1 Ground 2 TXP3

Page 61 - Supero Doctor III

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 62

5-28SUPERSERVER 5026Ti-BTRF User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating sy

Page 63 - Advanced Chassis Setup

Chapter 5: Advanced Motherboard Setup5-29Supero Doctor IIIThe Supero Doctor III program is a web-based management tool that supports remote management

Page 64 - 6-3 System Fans

5-30SUPERSERVER 5026Ti-BTRF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/util

Page 65 - System Fan Failure

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 66 - Overview

6-2SUPERSERVER 5026Ti-BTRF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelEach control panel on the front of the chassis must be con

Page 67

Chapter 6: Advanced Chassis Setup6-3Fan Confi gurationIn the 2U Twin2, each node (serverboard) controls the two fans that reside on its side of the cha

Page 68

6-4SUPERSERVER 5026Ti-BTRF User's ManualInstalling and Removing Hard DrivesInstalling a Hard Drive into the Drive CarrierEmpty drive carriers hav

Page 69 - 6-5 Node Installation/Removal

Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Removing a Dummy Drive Tray1111Installing/Removing Hot-swap DrivesTo remove a carrier, push the relea

Page 70

6-6SUPERSERVER 5026Ti-BTRF User's ManualFigure 6-5. Removing a Hard DriveFigure 6-6. Drives and Nodes: Logical Confi guration1B1ANode ANode BNote

Page 71 - 6-7 Power Supply

Chapter 6: Advanced Chassis Setup6-76-5 Node Installation/RemovalAs with any server system, power must be removed from the serverboard when upgrading

Page 72 - Release Tab

viiTable of Contents2-5 Checking the Serverboard Setup ...2-92-6 Preparing to Power

Page 73 - Chapter 7

6-8SUPERSERVER 5026Ti-BTRF User's ManualFigure 6-7. Removing a System Node121111

Page 74 - 7-2 Main Setup

Chapter 6: Advanced Chassis Setup6-96-6 Installing the Air ShroudsAir ShroudsAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC827 ch

Page 75

6-10SUPERSERVER 5026Ti-BTRF User's ManualRelease TabFigure 6-8. Removing the Power Supply

Page 76 - XBOOT Feature

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8SiT-F. The AMI ROM BIOS is stored in a Fl

Page 77

7-2SUPERSERVER 5026Ti-BTRF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory

Page 78 - Processor & Clock Options

Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time

Page 79

7-4SUPERSERVER 5026Ti-BTRF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to acces

Page 80 - SATA Confi guration

Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled an

Page 81

7-6SUPERSERVER 5026Ti-BTRF User's ManualXProcessor & Clock OptionsWarning: Take Caution when changing the Advanced settings. An incorrect val

Page 82

Chapter 7: BIOS7-7Execute-Disable Bit Capability (Available when supported by the OS and the CPU)Set to Enabled to enable the Execute Disable Bit whic

Page 83 - XPCI/PnP Confi guration

viii5-11 Onboard Indicators ...5-265-12 SATA Ports ...

Page 84 - XRemote Access Confi guration

7-8SUPERSERVER 5026Ti-BTRF User's ManualC3 Auto DemotionWhen enabled, the CPU will conditionally demote C6 or C7 requests to C3 based on un-core

Page 85 - Hardware Health Confi guration

Chapter 7: BIOS7-9Confi gure SATA asThis feature allows the user to select the drive type for SATA#1. The options are IDE, RAID and AHCI.PCH RAID CodeB

Page 86

7-10SUPERSERVER 5026Ti-BTRF User's ManualPIO ModeThe IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the program

Page 87

Chapter 7: BIOS7-11Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs. Select UDMA3 to allow the BIOS to

Page 88 - XACPI Confi guration

7-12SUPERSERVER 5026Ti-BTRF User's ManualPCIE I/O PerformaceThis feature selects the setting for the processor's PCIE maximum payload size.

Page 89 - XIPMI Confi guration

Chapter 7: BIOS7-13Serial Port NumberThis feature allows the user to decide which serial port to be used for Console Redirection. The options are COM

Page 90 - XEvent Log Confi guration

7-14SUPERSERVER 5026Ti-BTRF User's ManualWarning: Any temperature that exceeds the CPU threshold temperature predefi ned by the CPU manufacturer m

Page 91 - The options are Yes and No

Chapter 7: BIOS7-15even with the CPU fan running at full speed, the system buzzer will activate and the Overheat LED will turn on.The Early Alarm – th

Page 92 - 7-4 Security Settings

7-16SUPERSERVER 5026Ti-BTRF User's Manualbetter system cooling. The Performance setting is recommended for high-power-consuming and high-density

Page 93 - 7-5 Boot Settings

Chapter 7: BIOS7-17ACPI Version FeaturesThe options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanatio

Page 94 - 7-6 Exit Options

Chapter 1 Introduction1-1 OverviewThe Supermicro SuperServer 5026Ti-BTRF is "2U Twin2" server composed of the SC827H-R920B chassis and four

Page 95

7-18SUPERSERVER 5026Ti-BTRF User's ManualAddress must be manually entered below. If DHCP is selected, the next three items will be confi gured aut

Page 96

Chapter 7: BIOS7-19PCIE Error LogUse this option to enable logging of errors encountered in the system's PCIe bus. The options are Yes and No.

Page 97 - POST Error Beep Codes

7-20SUPERSERVER 5026Ti-BTRF User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass-words,

Page 98

Chapter 7: BIOS7-21Use this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify the sequence of priority f

Page 99 - BIOS Recovery

7-22SUPERSERVER 5026Ti-BTRF User's ManualXHard Disk DrivesThis feature allows the user to specify the sequence of priority from the available Har

Page 100

Chapter 7: BIOS7-23Save Changes and ExitWhen you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility a

Page 101 - System Specifi cations

7-24SUPERSERVER 5026Ti-BTRF User's ManualNotes

Page 102

Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the AMI BIOS. P

Page 103

A-2SUPERSERVER 5026Ti-BTRF User's ManualNotes

Page 104

Appendix B: BIOS Recovery B-1Appendix B BIOS RecoveryThe recovery procedure described in this section is to be used only when you are advised by your