Supermicro PWS-721P-1R Datasheet

Browse online or download Datasheet for Power supply units Supermicro PWS-721P-1R. Supermicro PWS-721P-1R power supply unit User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
YES
Value Units
100-240 Volts
7.0-3.5 Amps
50-60 Hz
720 Watts
Note: All measurements were taken with input voltage at 230 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 21.54%, 100% Load)
I
RMS
PF
A
5Vsb 0V
0.52 0.74 30.60 *10%
Low
88 8.28 4.93/0.3 0/0 73
83.10%
0.82 0.88 27.82 20%
Light
165 8.28 4.92/0.6 0/0 147
88.66%
1.81 0.95 26.01 50%
Typical
395 8.35 4.9/1.5 0/0 365
92.47%
3.53 0.97 21.54 100%
Full
789 8.22 4.87/3 0/0 728
92.31%
Tested by Electric Power Research Institute, Knoxville, TN.
92.47%
91.15%
SUPERMICRO
Ecos ID #
SO-40
Serial Number
Year
Manufacturer
N/A
2008
Model Number
P
WS-721P-1R
Output
Watts
12.14/5.92
12.19/11.79
12.17/29.43
12.13/58.82
Rated Output Power
Load
(%)
1U
Type
I
THD
(%) Input
Watts
Fraction
of Load
* 10% load results are for informative purposes only and not included in certification requirements.
** Fan power is not included in the efficiency calculations
Efficiency %
Test Date
Input Frequency
Rated Specifications
Input Voltage
Input Current
External
Fan (W)**
12V
DC Terminal Voltage (V)/ DC Load Current (A)
12/19/2008
Input and Output Power
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
20% 50% 100%
Loading (% of Rated Output Power)
Power (Watts)
Efficiency of the Power Supply
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Efficiency (%)
Efficiency %
Input Current and Voltage Waveforms
-400
-300
-200
-100
0
100
200
300
400
0 0.003 0.006 0.009 0.012 0.015
Time (s)
Voltage (V)
-15
-10
-5
0
5
10
15
Current (A)
Voltage Current