SC936 Chassis Manual
4-10
4-7 Power Supply
The SC936 chassis has an auto-switching power supply. This enables it to automati-
cally sense and operate at a 100v to 240v input voltage. An amber light illuminates
on the power supply when the power is off. An illuminated green light indicates that
the power supply is operating.
The SC936 chassis includes a redundant power supply that can be changed without
powering down the system. In the unlikely event that one is necessary, a new unit
can be ordered directly from Supermicro (see contact information in the Preface).
Changing the Power Supply
This chassis includes a redundant power supply which allows the server to 1.
remain running and one power supply to be removed. Remove the AC power
cord from the failed module.
Push the release tab on the power supply, as illustrated.2.
Pull the power supply out using the handle provided.3.
Change the failed power module with the same model.4.
Push the new power supply module into the power bay until you hear a click. 5.
Plug the AC power cord back into the module and power up the server.6.
Figure 4-9: Removing the Power Supply